Tilt the bracket about 45° and pass 

through the wire. 

In

Out

5

 

6

 

Open the wiring knockout.

To the right

To the left

Wiring knockout

Determine the horizontal direction (left or right) of 

the detector before installing the bracket on the wall.

7

 

Knockout with 4 × 20 tapping screw (screwkit)

Open the Up-Down lock screw knockout for 

connecting the bracket.

8

 

Wiring 

hole 

Wiring 

sponge pad 

In

Tighten screws  1  and  2 , adjust the bracket angle 

(refer to 2-2), then tighten screw  3 .

Perform an area check. If re-adjustment is required, 

loosen screw 3 and change the bracket angle.

After the adjustment is complete, tighten screw 3 

again.

Out

1

4 × 20 

screw

3 4 × 35 

Up-Down 

lock screw 

2

4 × 20 

screw

Adjustment 

screw 

9

 

Tighten the adjustment screw clockwise.

10

 

Wire to the terminal and install the main unit and 

lens on the base.

11

 

Install the shaft cover into place.

Summary of Contents for HX-40

Page 1: ...l HX 40AM HX 40 with anti masking HX 40DAM HX 40AM with micro wave 1 INTRODUCTION 1 1 BEFORE YOUR OPERATION 1 1 2 PARTS IDENTIFICATION 2 1 3 DETECTION AREA 3 2 INSTALLATION 2 1 MOUNTING WITH THE BRACKET 3 2 2 ADJUSTING THE VERTICAL ANGLE 5 2 3 MOUNTING WITHOUT THE BRACKET 5 2 4 WIRING 6 2 5 WALL TAMPER OPTION 6 3 WALK TEST 7 4 SETTING 4 1 FUNCTION 8 5 AREA ADJUSTMENT 10 6 LED INDICATION 10 7 SPECI...

Page 2: ... and reflection Heat source Objects moving in the wind Screw kit For joint For wall mounting For hood Screw 4 20 mm Screw 4 20 mm Screw 3 10 mm Lock screw attached on bracket base Bracket base Screw 3 10 mm Area masking seal Main unit Bracket LED indicator Lock screw M4 35 mm Lens Base PIR sensor Do not touch Terminals Shaft cover Cover Lock screw Hood Anti masking infrared LED HX 40AM DAM only Mi...

Page 3: ...ithout the bracket only if the following three conditions are met The mounting height 3 0 m 10 ft Horizontal direction adjustment is unnecessary The ground is level 90 90 20 20 Caution Do not change the detection length with bracket Use the masking seal to adjust the detection length 1 Remove the Up Down lock screw 2 Push the shaft cover clip outwards to remove the shaft cover Push with suitable t...

Page 4: ...he Up Down lock screw knockout for connecting the bracket 8 Wiring hole Wiring sponge pad In Tighten screws 1 and 2 adjust the bracket angle refer to 2 2 then tighten screw 3 Perform an area check If re adjustment is required loosen screw 3 and change the bracket angle After the adjustment is complete tighten screw 3 again Out 1 4 20 screw 3 4 35 Up Down lock screw 2 4 20 screw Adjustment screw 9 ...

Page 5: ...unit is already parallel to the ground Do not change the detection length by tilting the unit up or down Detection length should be adjusted with masking seal Refer to 2 1 for the details If the detection length is shorter than the designated one refer to page 3 change the detector angle upward If the detection length is equal to the designated one adjustments have been completed If the detection ...

Page 6: ... applicable universal magnet switch D 9 x W 40 x H 9 mm D 0 35 x W 1 57 x H 0 35 inches Universal magnet switch on the market assist is not included Bracket Main unit 9 5 18VDC N C COM N O SP SP SP SP T O N C AUX INPUT N C N C N C N C TAMPER TAMPER TROUBLE OUTPUT ALARM N C COM N O ALARM POWER POWER AUX INPUT 9 5 18VDC 1 TAMPER terminals to be connected to a 24 hour supervisory loop TAMPER OUTPUT N...

Page 7: ... ON OFF to ON Note The switch is set ON by factory default 3 2 Detected Not detected Note For the walk test move more than 1 0 m 3 3 ft away from the detector Conduct a walk test at least once a year Install the universal magnet switch wall side to the wall To determine the install position use the Install position template provided on the inside cover of the product package Open the wiring knocko...

Page 8: ...luding the following Infrared AIR sensors thermal line PIR sensors universal magnet switches etc AND Factory default OR When both the main unit and the satellite detect someone the alarm is output Set to this when not connecting a satellite unit When either the main unit or the satellite detects someone the alarm is output ON Factory default OFF Anti masking signal is output from TROUBLE OUTPUT te...

Page 9: ...eave any object within 1 0 m 3 3 ft from the unit MICROWAVE IMMUNITY POSITION FUNCTION STD Factory default MICRO WAVE IMMUNITY logic is not activated IMMUNITY MICRO WAVE IMMUNITY logic is activated Use this under harsh environment e g vegetation sway DIP switch 5 HX 40 HX 40AM HX 40DAM PIR SENSITIVITY POSITION FUNCTION HX 40 HX 40AM HX 40DAM MW RANGE SELECTOR MW SENSITIVITY ADJUSTMENT HX 40 HX 40A...

Page 10: ... 180 sec Masking detection Trouble output Anti Masking booting Anti Masking start up Masking detection Blinks 3 times and goes off for 3 sec and then repeats HX 40DAM Warm up Blinks for approx 60 sec Alarm Red lights for 2 sec PIR detection Green lights for 2 sec MW detection Yellow lights for 2 sec Green and Red blink 2 times simultaneously and go off for 5 sec This sequence is repeated for 180 s...

Page 11: ... 9 5 to 18 VDC 35 mA max at 12 VDC 40 mA max at 12 VDC 50 mA max at 12 VDC 2 0 1 sec Form C 28 VDC 0 2 A max N C 28 VDC 0 1 A max N C open when cover removed 20 C to 60 C 4 F to 140 F 95 max IP55 Wall 2 5 to 3 0 m 8 2 to 10 ft Vertical 20 Horizontal 95 Approx 60 sec LED blinks N C 28 VDC 0 1 A max N C 28 VDC 0 1 A max Red Warm up Alarm Red Warm up Alarm Trouble Red Warm up Alarm Trouble Green Warm...

Page 12: ...S B V The Netherlands URL http www optex eu OPTEX SECURITY SAS France URL http www optex security com OPTEX SECURITY Sp z o o Poland URL http www optex com pl OPTEX PINNACLE INDIA PVT LTD India URL http www optex net in en sec OPTEX KOREA CO LTD Korea URL http www optexkorea com OPTEX DONGGUAN CO LTD SHANGHAI OFFICE China URL http www optexchina com OPTEX Thailand CO LTD Thailand URL http www opte...

Reviews: