ENGLISH
FRANÇAIS
DEUTSCH
IT
ALIANO
ESP
AÑOL
PORTUGUÊS
EN-10
-DETECTION LENGTH ADJUSTMENT
To limit the detection length, apply the appropriate masking seal. Note that there are three different types of seal.
1
3
2
1
1
2
-AREA MASKING
9.0 m (30 ft.)
3.0 m (10 ft.)
5.5 m (18 ft.)
3.0 m (10 ft.)
4.0 m (13 ft.)
3.0 m (10 ft.)
-HX-40/40AM
DETECTOR CONDITION
LED INDICATOR (RED ONLY)
Warm-up
Blinks for approx. 60 sec.
Alarm
Lights for 2 sec.
Trouble
output
Anti-Masking
booting
(Anti-Masking
start up)
Blinks 2 times and goes off for 5 sec. and then repeats
for 180 sec.
Masking
detection
Trouble
output
Anti-Masking
booting
(Anti-Masking
start up)
Masking
detection
Blinks 3 times and goes off for 3 sec. and then repeats.
-HX-40DAM
Warm-up
Blinks for approx. 60 sec.
Alarm
Red lights for 2 sec.
PIR detection
Green lights for 2 sec.
MW detection
Yellow lights for 2 sec.
Green and Red blink 2 times simultaneously and go off
for 5 sec. This sequence is repeated for 180 sec.
Green and Red blink 3 times simultaneously and go off
for 3 sec. This sequence is repeated.
Red
Blink
Light
OFF
Green
(HX-40DAM only)
Yellow
(HX-40DAM only)
DETECTOR CONDITION
LED INDICATOR
1
2
3
4
5
6
7
8
9
0
1
9
2
8
3
7
4
6
5
56
Area masking seal
Pasting on example for masking No. 5 and No. 6
5
AREA ADJUSTMENT
6
LED INDICATION