ENGLISH
FRANÇAIS
DEUTSCH
IT
ALIANO
ESP
AÑOL
PORTUGUÊS
EN-6
2-4
WIRING
2-5
WALL TAMPER (OPTION)
Power wires should not exceed the following lengths.
WIRE GAUGE
HX-40
HX-40AM
HX-40DAM
12 V
14 V
12 V
14 V
12 V
14 V
AWG22 (0.33 mm
2
)
160
(520)
360
(1180)
140
(460)
310
(1020)
120
(390)
250
(820)
AWG20 (0.52 mm
2
)
260
(850)
560
(1840)
230
(750)
490
(1610)
180
(590)
390
(1,280)
AWG18 (0.83 mm
2
)
410
(1350)
900
(2950)
360
(1180)
780
(2560)
290
(950)
630
(2,070)
Universal magnet switch may be mounted as a wall tamper.
Installation space for universal magnet switch is provided on the back of the main unit and the bracket.
Maximum size of an applicable universal magnet switch: D 9 x W 40 x H 9 mm (D 0.35 x W 1.57 x H 0.35 inches)
Universal magnet switch on the market assist is not included.
Bracket
Main unit
9.5-18VDC
+
–
N.C.
COM
N.O.
SP
SP
SP
SP
T.O.(N.C.)
AUX
INPUT
(N.C.)
(N.C.)
(N.C.)
(N.C.)
TAMPER
TAMPER
TROUBLE
OUTPUT
ALARM
N.C.
COM
N.O.
ALARM
POWER
+
–
POWER
AUX
INPUT
9.5-18VDC
*1: TAMPER terminals to be connected to a 24 hour supervisory loop.
TAMPER OUTPUT (N.C.) *1
AUX INPUT (N.C.)
TROUBLE OUTPUT (N.C.)
S
PARE (Non short)
ALARM OUTPU
T (N.O.)
ALARM OUTPU
T (COM)
ALARM OUTPU
T (N.C.)
POWER INPU
T (-) (9.5 to 18 VDC)
POWER INPU
T (+) (9.5 to 18 VDC)
HX-40AM
HX-40DAM
HX-40
Magnet switch (Wall side)
installation position
Magnet switch (Base side)
installation position
Wiring Hole
Magnet switch
(Bracket side)
installation position
Magnet switch
(Wall side)
installation position