background image

_____________________________________________________________________________ 

  IP POWER                                                                                              PAGE 9 OF 32

 

 

 

 

 

Click 

IP 9258

 in the left of the window and the IP Power’s name and IP address 

will display in the right hand fields.  You can rename the IP Power or change its 
IP address or default gateway address.  Click 

Update

 to apply the new settings.  

The new settings will be working in 20 seconds. 

 

 

Double click the name of the IP Power, and your browser window will open and 
connect to the unit automatically.  Alternately, manually type the IP address of 
the IP Power into your browser. 

 

 

NOTE 

The IP Power 9258’s default IP address is 

192.168.0.50 

and its subnet mask is 

255.255.255.0

.  

The IP address of your computer should be in the same subnet with that of IP Power’s (by default 
this subnet is 

192.168.0.xxx

), so that you can access the IP Power control web pages. 

Typically, you will want to find out the IP address of your PC and set the IP Power to reside on the 
same subnet.  To find out the IP address of your PC: 

 

Select 

Start 

 Run

  

then type in

 cmd 

 

in the MS-DOS window, type in 

ipconfig

 

 

 

 

_____________________________________________________________________________ 

  IP POWER                                                                                              PAGE 10 OF 32

 

 

 

The IP address of the PC is 

192.168.100.31

, so the IP Power has been set to 

192.168.100.168

.  Both of these addresses are on the 

192.168.100.xxx

 subnet. 

Alternately you may change the PC’s IP address to be on the same subnet as the IP Power (by 
default 

192.168.0.50

), in 

Control Panel 

 Network Connections 

 Local Area Connection 

 

Properties 

 Internet Protocol (TCP/IP) Properties.

 

The default username and password of IP Power 9258 are: 

Username:

 admin 

Password:

  12345678  

 

PC or server software shutdown 

 

The IP Power 9258 can also safety shutdown a PC or server through the network 
before being powered off.  This allows you to remotely shut down a PC/server 
attached to IP Power 9258 using the usual Windows safe shutdown procedure.  
Before using the software shutdown function, please note:  

 

You will need to install the 

IP9258service.exe 

program from the IP Power CD as 

detailed below  

 

If you are running programs such as Microsoft Office the safe shut down may 
not automatically save open documents or files which may result in lost data.   

 

To allow enough time for the PC/server to safely shut down before being 
powered off, please set the delay time at 30 or 60 second on the IP Power 
control web pages 

Setup 

 Delay Switch

.  

 

 

The PC/server to shut down must be on the same Ethernet network and on 
the same subnet as the IP Power. 

 

Installing 

IP9258service.exe

 

 

 

Insert the IP Power CD in the PC/server which is to be enabled for software 
shutdown 

 

Install the 

IP9258config.exe 

, by selecting the 

SDK

 button on the LHS then 

selecting 

9258 SDK

 in the menu. Then double click Shutdown Program and run 

IP9258config.exe. 

On the install menu select the LHS bottom button to place 

the 

IP9258Service

 icon on your desktop. Click this icon   then select the 

IP9258config.exe

 program 

Summary of Contents for IP Power 9258

Page 1: ...5A current rating and use power OUT cables with 10A rating for each power outlet For the European Australian model IEC320 C13 220 250V outlets the individual max output current per outlet is 6A and th...

Page 2: ...ion Update details Feb 2007 1 1 Covers 1 38 firmware features July 2009 1 2 Added Telnet and SNMP firmware 1 5 2 and serial command line details firmware 1 5 3 WARNING Any changes to this equipment wi...

Page 3: ...OF 32 1 Introduction The IP power 9258 is a web browser controlled power switch that can be used easily for industrial or commercial power control With the remote network control technology a user co...

Page 4: ...20V use the 15A power cable Hardware installation Connect the IP Power to the hub using a Cat5 network cable for remote control you may then connect the hub or router to the Internet Connect the AC IN...

Page 5: ...s IP address to be on the same subnet as the IP Power by default 192 168 0 50 in Control Panel Network Connections Local Area Connection Properties Internet Protocol TCP IP Properties The default user...

Page 6: ...ol Using Browser To access the IP Power control web pages simply type the IP address of the IP Power into your web browser s address field _____________________________________________________________...

Page 7: ...ed IP address so that it is always known After changing the IP Power s IP address type the new address in the address field of your web browser You can also use the ipEdit exe tool to locate the IP Po...

Page 8: ...b pages Each receiver may be no more than 50 characters Subject The subject of the mail no more than 50 characters Mail Body Type the content of the mail here It must not be left blank _______________...

Page 9: ...onnected to the motherboard or the network port must be integrated into the motherboard After setting up the motherboard and network card use the WOL function by following two steps Go to Network Wake...

Page 10: ...nd menu Enter the IP address and port of the DynDNS server You can find this out on your PC by selecting Start Run then type in cmd and typing ping www dyndns com Enter the number in brackets e g 63 2...

Page 11: ...In the above example all outlets are off Example 2 The HTTP command http admin 12345678 192 168 0 50 Set cmd CMD SetPower P60 1 P61 0 P 62 0 P63 1 ____________________________________________________...

Page 12: ...mand syntax is case sensitive so be selective when using upper and lower case in command format The free tool wget is useful for sending these HTTP commands For example to send the command in Example...

Page 13: ...ans power OFF _____________________________________________________________________________ IP POWER PAGE 26 OF 32 Control outlet command snmpset v 1 c public 192 168 1 55 1 3 6 1 4 1 92 58 2 1 0 inte...

Page 14: ...for a full 5 seconds or until a sustained beep noise is heard this enables manual control mode which can be identified by the flashing outlet lights The outlet light that is not flashing is the one c...

Page 15: ...CONSOLE RS232 port to one of the console server serial ports for CM4001 2 this interconnection will use a standard UTP Cat 5 cable with a 319000 adapter at each end and all other console servers will...

Page 16: ...be a30 3 1c 7f 15 4 0 1 0 11 13 1a 0 12 f 17 16 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 port Enable serial command mode ipp_chat 0 ADEBUG9258 Z IP9258 DEBUG ON dev null Get current status status_nibble ipp_ch...

Reviews: