  IP POWER                                                                                              PAGE 3 OF 32

 

 

4)

 

Update IP Power with your browser 

 

 

Enter 

http://192.168.0.50

 (or the IP address assigned using 

IPEdit.exe

) in 

the browser of your locally connected PC and login: 

 

The default username is: 

admin 

The default password is:

 12345678  

 

You can now set the password and IP address, and modify the IP Power’s 
other settings.

 

 

5)

 

Control power outlets 

 

 

Click 

Set Power

 under 

Power 

to display the current state of each power outlet.  

Select 

On

 or 

Off

 and click 

Apply 

to manually control power to each outlet 

 

Click 

Power Schedule

 under 

System 

to program when each power outlet is to 

be automatically powered on or off 

 
 

 

 

 

_____________________________________________________________________________ 

  IP POWER                                                                                              PAGE 4 OF 32

 

 

Publishing history 

Date  

        Revision  

Update details  

Feb 2007         1.1 

Covers 1.38 firmware features 

July 2009         1.2 

Added  Telnet  and  SNMP  (firmware  1.5.2)  and  serial 
command line details (firmware 1.5.3)

 

 

 

 

 

 

 

 

 

 

WARNING 

 

Any changes to this equipment without permission may cause damages to your 
equipment! This equipment has been proven by CE & FCC to be prevented from the 
influence of harmful electronic jamming in normal business use conditions. 

 

IMPORTANT NOTICE 

1.

 

We have no responsibility for possible damage caused by improper usage or 
abnormal working environment 

2.

 

Do not use IP POWER in strong vibrating condition 

3.

 

Please contact the dealer If IP POWER works improperly 

Copyright © 2009 All rights reserved. No part of this publication may be reproduced, 
stored in a retrieval system, or transmitted in any form or by any means, electronic, 
mechanical, photocopying, recording or otherwise, without the prior written 
consent of us. All other products mentioned in this document are trademarks of 
their respective manufactures. We are exempt to notify any change of our products. 

Summary of Contents for IP Power 9258

Page 1: ...5A current rating and use power OUT cables with 10A rating for each power outlet For the European Australian model IEC320 C13 220 250V outlets the individual max output current per outlet is 6A and th...

Page 2: ...ion Update details Feb 2007 1 1 Covers 1 38 firmware features July 2009 1 2 Added Telnet and SNMP firmware 1 5 2 and serial command line details firmware 1 5 3 WARNING Any changes to this equipment wi...

Page 3: ...OF 32 1 Introduction The IP power 9258 is a web browser controlled power switch that can be used easily for industrial or commercial power control With the remote network control technology a user co...

Page 4: ...20V use the 15A power cable Hardware installation Connect the IP Power to the hub using a Cat5 network cable for remote control you may then connect the hub or router to the Internet Connect the AC IN...

Page 5: ...s IP address to be on the same subnet as the IP Power by default 192 168 0 50 in Control Panel Network Connections Local Area Connection Properties Internet Protocol TCP IP Properties The default user...

Page 6: ...ol Using Browser To access the IP Power control web pages simply type the IP address of the IP Power into your web browser s address field _____________________________________________________________...

Page 7: ...ed IP address so that it is always known After changing the IP Power s IP address type the new address in the address field of your web browser You can also use the ipEdit exe tool to locate the IP Po...

Page 8: ...b pages Each receiver may be no more than 50 characters Subject The subject of the mail no more than 50 characters Mail Body Type the content of the mail here It must not be left blank _______________...

Page 9: ...onnected to the motherboard or the network port must be integrated into the motherboard After setting up the motherboard and network card use the WOL function by following two steps Go to Network Wake...

Page 10: ...nd menu Enter the IP address and port of the DynDNS server You can find this out on your PC by selecting Start Run then type in cmd and typing ping www dyndns com Enter the number in brackets e g 63 2...

Page 11: ...In the above example all outlets are off Example 2 The HTTP command http admin 12345678 192 168 0 50 Set cmd CMD SetPower P60 1 P61 0 P 62 0 P63 1 ____________________________________________________...

Page 12: ...mand syntax is case sensitive so be selective when using upper and lower case in command format The free tool wget is useful for sending these HTTP commands For example to send the command in Example...

Page 13: ...ans power OFF _____________________________________________________________________________ IP POWER PAGE 26 OF 32 Control outlet command snmpset v 1 c public 192 168 1 55 1 3 6 1 4 1 92 58 2 1 0 inte...

Page 14: ...for a full 5 seconds or until a sustained beep noise is heard this enables manual control mode which can be identified by the flashing outlet lights The outlet light that is not flashing is the one c...

Page 15: ...CONSOLE RS232 port to one of the console server serial ports for CM4001 2 this interconnection will use a standard UTP Cat 5 cable with a 319000 adapter at each end and all other console servers will...

Page 16: ...be a30 3 1c 7f 15 4 0 1 0 11 13 1a 0 12 f 17 16 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 port Enable serial command mode ipp_chat 0 ADEBUG9258 Z IP9258 DEBUG ON dev null Get current status status_nibble ipp_ch...

Reviews: