HOBO U30 Station/RC
S e r v e r S e t u p O p t i o n s
The following sections describe the configurable parameters for the U30/Wi-Fi within the
Server
configuration menu.
Options
Network Mode
Select the network mode for the U30.
0 = Wired Only
1 = Wireless Only (default)
2 = Bridging,<One Host>
IP Address
If DHCP is not used to assign IP addresses, enter it manually. The IP address must be set to a unique
value in the network.
Enter each octet and press
Enter
between each section inputted.
The current value is displayed in parentheses.
Set Gateway IP Address ?
The gateway address, or router, allows communication to other LAN segments. The gateway address
should be the IP address of the router connected to the same LAN segment as the unit. The gateway
address must be within the local network.
The default is N (No), indicating the gateway address has not been set.
To set the gateway address, type
Y
. At the prompt, enter the gateway address.
Netmask
A netmask defines the number of bits taken from the IP address that are assigned for the host part.
Netmask: Number of Bits for Host Part (0=default)
The unit prompts for the number of host bits to be entered, then calculates the netmask, which displays in
standard decimal-dot notation when the saved parameters are displayed (for example, 255.255.255.0).
Set DNS Server IP Address ?
Default = N
Change telnet config password ?
Setting the Telnet configuration password prevents unauthorized access to the setup menu via a Telnet
connection to port 9999 or via web pages. The password must have 4 characters.
Note: A password is not required to access the Setup Mode window via a serial connection.
Default = N