22
Installation & Operation Guide: Oncam Grandeye 360
o
Evolution Camera Range
Version 2.4 | January 2014 | Oncam Grandeye, 115 Hammersmith Road, London. W14 0QH. UK
T: +44 (0)20 7371 6640 | E: [email protected] | W: www.oncamgrandeye.com
5.4
Installation
5.4.1
Wall Mount
The wall mount cleat plate (3) is first fastened to the wall surface using fasteners (not supplied) which are
appropriate for the wall material and which are capable of supporting at least four times the weight of the wall mount
and camera. Be sure that the arrow mark on the plate is oriented up. Cables are passed through one of the holes in
the plate. The wall mount arm is then hooked over the top tabs on the cleat plate and the two set screws on the
bottom are tightened to lock the arm to the cleat plate. Cables are passed through the mount arm and out the
threaded hole on the end of the arm.
5.4.2
Installation on Rough Surfaces or Over Electrical Boxes
If the mount is to be installed over an electrical box, or if the wall surface is uneven, the wall mount plate (4) is first
fastened to the box or the wall surface and then the cleat plate is fastened to it using the two nuts and washers
provided. This provides an even surface for the cleat plate to work with.
5.4.3
Pendant Adapter – Evolution Outdoor Housing
The Outdoor Evolution camera housing requires the use of a OBE-01-O#A
(#=W : white / #=B : black)
pendant
adapter (sold separately) to fit it to the wall mount. Cabling is passed through the adapter, which is then threaded
onto the mount arm. The rotation set screw (2) is tightened to lock the camera into the desired rotational
orientation. The outdoor enclosure base is then mounted to the pendant adapter with the cables passing through
the IP66 grommets in the back of the enclosure.
5.4.4
Pendant Adapter – Evolution Indoor Housing
The Indoor Evolution camera housing requires the use of the OBE-01-I#A
(#=W : white / #=B : black)
pendant
adapter and the OXM-03-UWA adapter (sold separately) to fit it to the wall mount. Cabling is passed through the
gender adapter, which is then threaded onto the mount arm. The indoor pendant adapter is then threaded onto the
gender adapter. The rotation set screw (2) may be tightened to lock the camera into the desired rotational
orientation. The indoor enclosure base plate is then mounted to the pendant adapter with the cables passing
through it.
Mounting directly to an electrical box may not provide sufficient
mechanical strength to withstand a physical blow to the mount arm.
We do not recommend mounting to electrical boxes when the camera is
within reach. When mounting to an electrical box, make sure that
the box is structurally sound enough to support the camera.