7. Connection Procedure
9
Type http://192.168.1.200
/ in the address bar (
) of
Internet Explorer.
The Reader Status Window is
displayed. Click the
Reader
Settings
Button.
The V750 Operation Warning
Dialog Box is displayed. Click
the
OK
Button.
10
The Reader Settings Window
shows the Ethernet settings.
Make the settings as follows and
click the Save Button.
Host Name
:V750-BA50C04-US
Domain Name
:Blank
DHCP: OFF
IP Address
:192.168.250.2
Subnet Mask
:255.255.255.0
Gateway
:192.168.1.254
TCP/IP Port
:7090
*If the settings are different from
the above, change the
corresponding set values.
Exit Internet Explorer.
*If Internet Explorer does not
exit, the IP address of the RFID
Reader/Writer will be changed
and the screen will not be
displayed.
*The gateway setting is unnecessary. However, if you
leave the Gateway Field blank, an error will occur.
Therefore, use the default setting.
16