Boot Options
The boot option settings specify the location of downloadable firmware and configuration files and their optional
parameters, and the location of a syslog server to which all reader events may be sent.
Item
Describe
Setting
Requirement
Default
Boot Config
Options
Optional parameters used when downloading a new
configuration file to the reader. It is not supported on the
firmware version 2.2.22.
Optional (none)
Boot Config
URI to the tm.conf file to be downloaded on startup. Specify
local:default for local tm.config file. It is not supported on
the firmware version 2.2.22.
Optional (none)
Boot Firmware
Options
Same as Boot Config Options used when downloading new
firmware to the reader.
Following four parameters are available as a user
specifiable option.
-f
/
--force
Force a downgrade if config file
version is lower than that currently
running on the reader.
-w / --wipe
Wipe flash memory and settings
-p / --preserve Preserve configuration settings under
a wipe.
-a / --auto
Add the reader’s MAC address to
download filename.
Optional (none)
Boot Firmware
URI to the firmware file to be downloaded at startup.
Optional
(none)
Syslog Host
Name of host for remote logging. All log levels in syslog will
be sent to this host. Syslog message includes information
of events occurring in V740 reader as below.
(a)
Boot message
(b)
Query page display and query performance
(c)
Log-in by telnet, SSH
(d)
Change of setting values
(e)
Firmware upgrade
Optional (none)