RFID Protocol Settings
The RFID protocol settings take effect immediately on the reader upon saving them. A restart is not required.
The Default RQL Query runs continuously at startup and thus a change to this setting requires a restart of the
reader.
Item
Describe
Setting
Requirement
Default
UHF Power
(dBm)
UHF Output power in dBm. This setting must be adjusted
carefully to comply with FCC regulations.
Mandatory 30.0
EPC1 Tag ID
length
Radio buttons that enable combined 96- and 64-bit tag
support or single tag id lengths. If the reader will only be
reading 96- or 64-bit tags, select that radio button to
optimize read rates.
Optional 64-bit/96-bit
EPC0 Search
Depth
Maximum number of EPC0 tags to be singulated on each
query.
(This function is not available as this type of the V740
reader does not support EPC0 protocol.)
Optional 80
Default RQL
Query
Initial query to be run continuously when reader starts up.
The most recent command entered is performed
automatically and continuously every second after
rebooting the reader.
Once a user program has connected to port 8080, the
results of the command will be available.
Optional (none)