background image

 

 

User Manual 

For 

WMP-ND03B 

無線網路卡

 

Mini-PCI Card 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Version: 1.1 

2008/6/12 

C

om

pan

C

on

fiden

tial

Summary of Contents for WMP-ND03B

Page 1: ...User Manual For WMP ND03B 無線網路卡 Mini PCI Card Version 1 1 2008 6 12 C o m p a n y C o n f i d e n t i a l ...

Page 2: ...prietary information and is the property of Alpha Networks Corporation The contents of this document may not be disclosed to unauthorized persons without the written consent of Alpha Networks Corporation C o m p a n y C o n f i d e n t i a l ...

Page 3: ...vision History Rev Date Author Reason for Changes 1 0 2008 3 14 Alfred Chin New release 1 1 2008 6 12 Alfred Chin Add band 4 5725 5850MHz in item 2 2 1 3 and 2 2 4 3 C o m p a n y C o n f i d e n t i a l ...

Page 4: ... Section 8 2 2 2 IEEE 802 11b Section 9 2 2 3 IEEE 802 11g Section 9 2 2 4 IEEE 802 11 Draft n Section 10 2 2 5 General Section 11 2 3 COMPATIBILITY REQUIREMENTS 12 2 4 REGULATORY REQUIREMENTS 12 2 5 REQUIREMENTS OF RELIABILITY MAINTAINABILITY AND QUALITY 13 2 6 ENVIRONMENTAL REQUIREMENTS 13 END PRODUCT LABELING 15 MANUAL INFORMATION TO THE END USER 15 C o m p a n y C o n f i d e n t i a l ...

Page 5: ...n the directory C v0_5_b25ALL art_driver bin 2000 Execute the uninst_new_drv_2k bat Execute the inst_new_drv_2k bat WinXP OS Enter in the directory C v0_5_b25ALL art_driver bin xp Execute the uninst_new_drv_xp bat Execute the inst_new_drv_xp bat 2 Insert the card then install the driver the driver is located at Win2000 OS C v0_5_b25ALL art_driver bin 2000 WinXP OS C v0_5_b25ALL art_driver bin xp C...

Page 6: ...ontinuous receive test For example press o to change 11g or 11b test mode Press c to continuous transmit mode 2 Continuous Transmit Options a Before the Continuous Transmit test need to press e first The command will load the calibrate data to the EEROM then the card can transmit the target power b The channel frequency data rate and output power could be changed in continuous transmit options Pre...

Page 7: ... 54Mbps for IEEE 802 11g 11Mbps for IEEE 802 11b and 300Mbps for IEEE 802 11n to connect your wireless LAN With seamless roaming fully interoperability and advanced security with WEP standard 802 11a b g n Mini PCI Card offers absolute interoperability with different vendors 802 11g 802 11b 802 11 draft n Access Points through the wireless LAN 1 2 Product Features Ÿ Compatible with IEEE 802 11a hi...

Page 8: ...nd Modulation Type Ÿ BPSK QPSK 16QAM 64QAM with OFDM 2 2 1 3 Operating Frequency CE 5150 5350MHz 5470MHz 5725MHz C Tick 5150 5350MHz 5470MHz 5725MHz 5725MHz 5850MHz FCC 5150 5250MHz 5725MHz 5850MHz IC 5150 5250MHz 5725MHz 5850MHz Taiwan NCC 5250 5350MHz 5725MHz 5850MHz Japan TELEC 5150 5350 5470 5725MHz 2 2 1 4 Data Rate Ÿ 54 48 36 24 18 12 9 and 6Mbps 2 2 1 5 Media Access Protocol CSMA CA with AC...

Page 9: ...2Mbps Ÿ 90dBm at 5 5Mbps Ÿ 88dBm at 11Mbps 2 2 3 IEEE 802 11g Section Feature Detailed Description 2 2 3 1 Standard Ÿ IEEE 802 11g 2 2 3 2 Radio and Modulation Type Ÿ BPSK QPSK 16QAM 64QAM with OFDM 2 2 3 3 Operating Frequency Ÿ 2400 2483 5MHz ISM band 2 2 3 4 Channel Numbers Ÿ 11 channels for United States Canada Taiwan 13 channels for Europe Countries Japan 2 2 3 5 Data Rate 6 9 12 18 24 36 48 5...

Page 10: ...850MHz n Japan TELEC 2400 2483 5MHz 5150 5350 5470 5725MHz GI 800ns GI 400ns MCS 20MHz 40MHz 20MHz 40MHz 0 6 5 13 5 7 2 15 1 13 27 14 4 30 2 19 5 40 5 21 7 45 3 26 54 28 9 60 4 39 81 43 3 90 5 52 108 57 8 120 6 58 5 121 5 65 0 135 7 65 135 72 2 150 8 13 27 14 444 30 9 26 54 28 889 60 10 39 81 43 333 90 11 52 108 57 778 120 12 78 162 86 667 180 13 104 216 115 556 240 14 117 243 130 000 170 2 2 4 4 ...

Page 11: ...m at MCS1 9 Ÿ 83dBm at MCS2 10 Ÿ 80dBm at MCS3 11 Ÿ 78dBm at MCS4 12 Ÿ 74dBm at MCS5 13 Ÿ 73dBm at MCS6 14 Ÿ 70dBm at MCS7 15 n 2 4GHz Band HT 40 Ÿ 82dBm at MCS0 8 Ÿ 82dBm at MCS1 9 Ÿ 80dBm at MCS2 10 Ÿ 77dBm at MCS3 11 Ÿ 75dBm at MCS4 12 Ÿ 71dBm at MCS5 13 Ÿ 70dBm at MCS6 14 Ÿ 67dBm at MCS7 15 2 2 5 General Section Feature Detailed Description 2 2 5 1 Antenna Connector Ÿ R SMA connectors 2 2 5 2 ...

Page 12: ...ements Feature Detailed Description 2 4 1 United States IEEE 802 11a n EMI FCC Part 15 407 b Power Limits FCC Part 15 407 a IEEE 802 11b g n FCC part 15 247 15 205 15 209 Safety UL1950 3 for CSA mark 2 4 2 Europe IEEE 802 11a n Ÿ EMC EN 301 489 1 and 17 EN 60950 Ÿ DFS TPC 301 893 IEEE 802 11b g n Ÿ EMC EN 300 328 EN 300 826 EN 60950 2 4 3 Japan IEEE 802 11a n Ÿ ARIB STD T71 IEEE 802 11b g n Ÿ ARIB...

Page 13: ...operation when operating in ambient temperature of 0 to 40 2 6 2 Non Operating Temperature Conditions Ÿ Neither subassemblies is damaged nor the operational performance is degraded when restored to the operating temperature after exposing to storage temperature in the range of 20 to 75 2 6 3 Operating Humidity conditions Ÿ The product is capable of continuous reliable operation when subjected to r...

Page 14: ... of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment IMPO...

Page 15: ...en the antenna and users The final end product must be labeled in a visible area with the following Contains FCC ID RRK WMPND03B Manual Information To the End User The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the user s manual of the end product which integrates this module The end user manual shall include all r...

Page 16: ...tween the antenna and users and 2 The transmitter module may not be co located with any other transmitter or antenna 3 For all products market in CANADA OEM has to limit the operation channels in CH1 to CH11 for 2 4G band by supplied firmware programming tool OEM shall not supply any tool or info to the end user regarding to Regulatory Domain change As long as 3 conditions above are met further tr...

Page 17: ...ominent location IMPORTANT NOTE To comply with FCC RF exposure compliance requirements The antenna must not be co located or operating in conjunction with any other antenna or transmitter If the end product integrating this module is going to be operated in 5 15 5 25GHz frequency range the warning statement in the user manual of the end product should include the restriction of operating this devi...