5-7-17 I/O Automatic Changeover setting (CA)
This function alternately turns the output terminals (OUT3 and OUT4) ON and OFF for
Multiple Repeat and EAS. Check commands every time the command is issued. This is used to
switch multiple antennas automatically.
Enable the function when a special antenna that requires this function is used. Otherwise,
disable the function.
<Command
Format>
STX
Node No.
Command
code
“
CA”
Output ETX BCC
1 2
2 1
1
1
Specifies the enabled/disabled state of the output signal.
Specification range: 0,1, (Factory default: 0)
When * is specified, the currently specified value is read.
Specified number
0
1
*
Output
Disabled
Enabled -
<Response
Format>
STX Node
No. Retry
flag
Command
code
“
CA”
Response
Code
“
00
”
Output
ETX BCC
1 2 1 2
2 1
1
1
Response Code
00:Normal Completion
For other Response Codes, refer to SECTION 5-3-7 Response Code List.
Output Output
value
Displays
the specified output value.
:・
The setting is enabled after reset by the Reset Command. To enable the setting at the next
start-up, the setting must be saved by Set Value Writing (EW).
・
Alternately, the OUT3 and OUT4 on the Reader/Writer are turned ON and OFF.
・
This function is applied only for Multiple Repeat read and EAS check (and offline EAS check)
command in ISO mode, and EAS check (and offline EAS check) command in I.CODE1 Mode.
The function is not activated by other commands.
・
When the function is enabled, the control of OUT3 and OUT4 by I/O Control Command (CC) is
unavailable. To control OUT1 and OUT2, specify * for the OUT3 and OUT4 values.
Example) When OUT1:ON, OUT2:OFF, Note No. 00 [STX]00CC10**[ETX][BCC]