2-2
Specifications
2-2
2-4
2-2-1 General Specifications
Item
Specifications
Supply voltage
24VDC ±10%
Power consumption
27 W or less
Ambient operating
temperature
-10
℃
to 50
℃
(with no icing)
Ambient operating humidity
35% to 85% RH (with no condensation)
Ambient storage temperature
-25
℃
to 65
℃
(with no icing)
Insulation resistance
20 M
Ω
min. (by a 100 VDC mega) between both
I/O terminals and both power supply terminals,
between both COM terminals, and between both
ANT terminals
Dielectric strength
Leakage current of 10 mA max. at 1000 VAC
(50/60 Hz) for 1 minute in any of the above
combinations
Vibration resistance
No abnormal condition after applying 10 sweeps
of a vibration of 10 to 150 Hz and 0.2mm double
amplitude in X, Y, and Z directions for eight
minutes
Shock resistance
No abnormal condition after giving an impact of
150 m/s
2
three times each in X, Y, and Z
directions, i.e., 18 times in total
Grounding
Connecting to a ground of 100
Ω
or less
Dimensions
247 x 84 x 128 mm (W×H×D)
Protective construction
IP60 (IEC60529 Standard)
Number of terminals for
antenna connection
Transmitting/receiving antenna: 1
Receive-only antennal: 1
Material
Aluminum die casting
Mounting method
Fastening with M6 screws
Standby time
*1
15
min
Weight
Approx. 1.6 kg
:
(*1) The time that elapses after turning power ON to getting stable for
communication.
2-2-2 Performance Specifications
Item
Specifications
Self-diagnostics
CPU Error, System Error, Host communication
Error, Tag Communication Error.
Initialization process at power-on
During the initialization process after power-on, four LED indicators: RUN, COMM, NORM, and ERROR light up.