Section 4
Installation and Connections
V680-D1KP58HTN
Use the following procedure to install an RF Tag with the V680-A80 Attachment.
1.
Attach the Attachment to the workpiece.
2.
Tighten the lock nut.
Use a tightening torque of 21 to 42 N
·
m.
3.
Place the RF Tag in the Attachment.
The RF Tag can be attached in either direction. The direction does not
affect operation.
4.
Insert the split pin into the 3.2-diameter hole and spread open
the end of the pin to prevent it from coming out.
Refer to
RF Tag Installation Precautions
for information on the effect of metal at the back surface,
Mutual Interference of RF Tags and Influence of Inclination of the V680-D1KP58HTN.
Mo
u
nting Hole Dimensions
M12
Split pin
Nominal dimensions: 3.2-mm dia.
×
20-mm length
Two nuts and one split pin are provided with the V680-A80 Attachment. You must provide any replacement split pins.