Section 7
Host Communications Specifications
207
RFID System
User's Manual
(Modbus TCP)
RESET
This query resets the Reader/Writer.
Query Format
Response Format
Normal Response
Error Response
Execution Example
Resetting the Reader/Writer
TX: 000000000009FF10D0000001020000
RX: 000000000006FF10D0000001
Parameter
Description
Register address
The register address (D000 hex) that specifies the reset setting
Word count
The number of words for the option (0001 hex)
Number of bytes for option The number of bytes for the option (02 hex)
Option
0000 hex: Normal reset
FFFF hex: Forced reset
Parameter
Description
Register address
Contains the register address that was specified in the query.
Word count
Contains the word count that was specified in the query.
Note:
When forced reset, the response will not be returned.
Parameter
Description
Exception code
For details, refer to
in this section.
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Byte 9
Byte 10
Byte 11
Byte 12
Byte 13
Byte 14
Transaction
identifier
Protocol
identifier
Field length
Unit
identifier
Function code
Register
address
Word count
Number of bytes
for option
Option
X
X
0000 hex
0009 hex
FF hex
10 hex
D000 hex
0001 hex
02 hex
2 bytes
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Byte 9
Byte 10
Byte 11
Transaction
identifier
Protocol
identifier
Field length
Unit
identifier
Function code
Register address
Word count
X
X
0000 hex
0006 hex
FF hex
10 hex
D000 hex
0001 hex
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Transaction
identifier
Protocol identifier
Field length
Unit
identifier
Function
code
Exception
code
X
X
0000 hex
0003 hex
FF hex
90 hex
1 byte