![Omron V680S Series User Manual Download Page 212](http://html.mh-extra.com/html/omron/v680s-series/v680s-series_user-manual_743116212.webp)
210
Se
ct
io
n 7
Me
ss
age
Det
a
ils
RFID System
User's Manual
(Modbus TCP)
Section 7
Host Communications Specifications
GET COMMUNICATIONS DIAGNOSTIC INFORMATION
This query gets the most recent communications diagnostic information.
The communications diagnostic information is not returned if communication diagnostic is disabled.
Query Format
Response Format
Normal Response
Parameter
Description
Register address
The register address (CA00 hex) that specifies reading the communication diagnostic information
Word count
The number of words in the communication diagnostic setting to read (000E hex)
Parameter
Description
Byte count
The number of bytes in the communication diagnostic information that was read (1C hex)
Communications diagnostic
information
The information will be all zeros if communication diagnostic is enabled and there are no
communications diagnostic results.
The information will be all zeros if communication diagnostic is disabled.
Operating time
Contains the system operating time for communication diagnostic in 8-digit hexadecimal.
00000000 to FFFFFFFF hex (unit: ms)
Query type
Contains the query type for communication diagnostic in 4-digits hexadecimal.
0001 hex : READ ID
0002 hex : READ DATA
0003 hex : WRITE DATA
0004 hex : LOCK
0005 hex : DATA FILL
0006 hex : RF TAG OVERWRITE COUNT CONTROL
0007 hex : RESTORE DATA
0008 hex : COPY DATA
Communications
result
Contains the error code for communication diagnostic in 4-digits hexadecimal.
(This is the upper word of the end code in response to the RF Tag communications query.)
0000 hex : Normal end
0003 hex : Communications precaution
2001 hex : RF Tag missing error
2002 hex : RF Tag communications error
2003 hex : Tag ID mismatch error
2004 hex : RF Tag address error
2005 hex : RF Tag lock error
2006 hex : RF Tag verification error
2007 hex : RF Tag data lost error
2008 hex : RF Tag system error
2009 hex : RF Tag overwriting error
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Byte 9
Byte 10
Byte 11
Transaction
identifier
Protocol identifier
Field length
Unit
identifier
Function code
Register address
Word count
X
X
0000 hex
0006 hex
FF hex
03 hex
CA00 hex
000E hex
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Byte 9
···
Byte 36
Transaction
identifier
Protocol identifier
Field length
Unit
identifier
Function
code
Byte count
Communications diagnostic information
X
X
0000 hex
001F hex
FF hex
03 hex
1C hex
(28 bytes)
Byte 9
···
Byte 12
Byte 13
Byte 14
Byte 15
Byte 16
Byte 17
Byte 18
Byte 19
Byte 20
Byte 21
Byte 22
Byte 23
Byte 24
Byte 25
Byte 26
Byte 27
···
Byte 34
Byte 35
Byte 36
Operating time
Query type
Communications
result
Diagnostic result
Send power level
Receive power
level
Noise level
Power level
Tag ID data
(Reserved)
4 bytes
2 bytes
2 bytes
2 bytes
2 bytes
2 bytes
2 bytes
2 bytes
8 bytes