69
Heat-resistive RFID System
User's Manual
S
e
c
tion 4
Communic
a
tions
Comma
nds
Section 4
Reading from/Writing to Tags
• Example
Writing two bytes of data “1122” from address 0010h of the Tag in the communications area to
Controller No. 2., and returning a response (hexadecimal code) for the polling processing results
request.
Name
Details
End code
Indicates the execution result for the command.
The end code 00 indicates normal completion.
74: Tag was not in range when polling auto processing results were requested
75: Tag was not in range when polling auto processing was aborted.
76: Tag was communicating or processing had completed when polling auto processing was
aborted.
Read data
Displays the read data according to the execution details (command).
Subcommand Response
P
W
0
0
2
2
×
×
2
@
×
×
3
*
CR
2
End code
FCS
Terminator
Command code
Controller No.
Command
1
1
P
W
2
2
Write data
1
0
H
1
0
0
2
1
1
4
4
@
0
2
3
0
2
*
CR
2
3
Data
type
Antenna
designation
Start address
FCS
Controller No.
Terminator
Command
code
Response
P
W
4
6
7
4
2
2
2
@
0
2
3
*
CR
2
End code
FCS
Terminator
Command code
Controller No.
Subcommand
P
W
3
7
C
1
2
1
2
@
0
2
3
*
CR
2
1
Data
type
Antenna
designation
FCS
Controller No.
Terminator
Command
code
Subcommand Response
P
W
0
0
2
2
4
5
2
@
0
2
3
*
CR
2
End code
FCS
Terminator
Command code
Controller No.