39
Heat-resistive RFID System
User's Manual
Se
c
tion 3
l
Sw
it
ch S
e
tt
ings
Section 3
Before Communications
Setting Methods
Use the provided screwdriver to make switch settings as shown in the following diagram.
Default Settings
The following table shows the default settings (factory settings).
•
Rotary switch settings
•
DIP switch settings
SW1
0 1
2
3
45
6
7
8
9
0 1
2
3
45
6
7
8
9
1
2
3
4
5
6
7
8
O
N
1
2
3
4
5
6
7
8
O
N
SW2
Name
Default setting
Details
SW1
SW2
SW3-1
SW3-2
SW3-3
SW3-4
SW3-5
SW3-6
SW3-7
SW4-1
SW4-2
SW4-3
SW4-4
SW4-5
SW4-6
SW4-7
SW4-8
SW3-8
Node number
Reserved by the system.
Reserved by the system.
Reserved by the system.
Reserved by the system.
Reserved by the system.
Reserved by the system.
Baud rate
Data length
Parity
Number of stop bits
Reserved by the system.
Reserved by the system.
Reserved by the system.
CD1D
CD2D
Not used.
RS-485 terminating resistance
0
0
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Node number 0
Set to 0.
Always OFF
Always OFF
Always OFF
Always OFF
Always OFF
38,400 bps
7 (ASCII7)
Even
2
Always OFF
Always OFF
Always OFF
(Not used.)
No terminating resistance
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Reserved by the system.
Always OFF
SW3 (left)
SW4 (right)