31
Heat-resistive RFID System
User's Manual
Se
c
tion 2
RS
-23
2
C Inter
fa
ce C
o
n
n
e
c
tions (V
6
80-CA1
D)
Section 2
Installation, Connections, and Wiring
• Assembling the Connector
1.
Prepare the end of the cable as shown below.
2.
Solder the conductors to the plug pins.
3.
Attach housing A2 of the Hood to the Plug and secure the aluminum-taped portion with the cable
clamp.
4.
Secure the two connector fixing screws and put on housing B2 to complete the connector assembly.
Conductors
Braided shield
Shield tape
Cable bushing
•
Insert the cable into the cable bushing.
•
Unravel the braided shield for approximately 10 mm and
fold it back on the cable bushing.
•
Apply shield tape to the folded braided shield.
Plug
Jumper
Aluminum tape
Cable bushing
Note: Short-circuit pins 7 (RS) and 8 (CS) with a jumper.
Pin No.
Symbol
Name
Shield
GR
Ground
5
SG
Signal ground
3
SD
Send data
2
RD
Receive data
7 (See note.)
RS
Request to send
8 (See note.)
CS
Clear to send
Two, M2.6 lock screws
Housing A2
Cable clamp
Housing B2