Installation, Connections, and Wiring
Wiring
Wire the Controller as shown below.
Power Supply and Ground Wires
• The power supply and ground terminals use M3 self-rising screws. The following type of crimp termi-
nals can be connected to these terminals. Tighten each screw to a torque of approximately 6 kgf·cm.
• Examples of Applicable Crimp Terminals
• The Controller can internally withstand the noise on the power line. By providing power to the Con-
troller through the noise filter, however, the noise between the Controller and ground can be greatly
reduced.
Manufacturer
Model
Applicable wire
Type
J.S.T. Mfg. Co., Ltd.
1.25-N3A
AWG24 to AWG16
Fork-shaped
J.S.T. Mfg. Co., Ltd.
1.25-Y3A
V680-CA1D
Connection Example
+24 VDC
0 V
Line filter
Ground at a resistance
of 100
Ω
or less
Ferrite core (provided)
6.5 max.