94
NC Unit Error Logs
Section 10-1
Initial speed
Initial speed error
1000
The axis parameters’ initial speed
setting exceeds the maximum
speed setting for an axis.
In this condition, only the data
transfer (read or write) and data
save operations can be performed.
All of the axis parameters will be
returned to their default values.
After correcting the appropriate
axis parameters, reset the power
supply or restart the NC Unit.
Initial pulse designa-
tion error
1001
The initial pulse designation is not
set to 0000 or 0001.
Maximum
speed
Maximum speed
error
1010
The axis parameters’ maximum
speed setting is outside the setta-
ble range (1 to 500 kpps).
Acceleration/
deceleration
data
Acceleration time
error
1310
The axis parameters’ origin search
acceleration time setting is out-
side the settable range (0 to 250
s).
Deceleration time
error
1320
The axis parameters’ origin search
deceleration time setting is outside
the settable range (0 to 250 s).
Acceleration/deceler-
ation curve error
1330
The axis parameters’ acceleration/
deceleration curve setting is not 0
or 1.
Positioning monitor
time error
1332
The axis parameters’ positioning
monitor time setting is outside the
settable range (0 to 9999 ms).
Origin search
Origin compensation
error
1600
The axis parameters’ origin com-
pensation setting is outside the
settable range (-1,073,741,823 to
1,073,741,823 pulses).
Origin search high
speed error
1601
The axis parameters’ origin search
high speed setting exceeds the
axis parameters’ maximum speed
setting.
Origin search prox-
imity speed error
1602
The axis parameters’ origin search
proximity setting exceeds the axis
parameters’ maximum speed set-
ting.
Origin search speed
inconsistent
1603
The axis parameters’ origin search
high speed setting is less than or
equal to the origin search proximity
speed setting.
Operation mode
selection error
1604
The axis parameters’ origin search
operating mode selection setting is
not 0, 1, 2, or 3.
Origin search opera-
tion error
1605
The axis parameters’ origin search
operation setting is not 0, 1, or 2.
Origin search direc-
tion error
1606
The axis parameters’ origin search
direction is not 0 or 1.
Origin detection
method error
1607
Even though the axis parameters’
origin search operation is not set
to single-direction mode, the origin
detection method setting is not 0,
1, or 2.
Group
Name
Code
Cause
Remedy
Summary of Contents for SYSMAC W398-E1-1
Page 1: ...23 5 7 21 0 18 Cat No W398 E1 1 SYSMAC WS02 NCTC1 E CX Position...
Page 2: ......
Page 3: ...WS02 NCTC1 E CX Position Operation Manual Produced July 2001...
Page 4: ...iv...
Page 10: ......
Page 76: ......
Page 80: ......
Page 94: ......
Page 100: ......
Page 104: ......
Page 124: ......
Page 126: ......