I/O Refreshing Operation ..........................................................................................................5 - 9
Input Range and Converted Values
6-1 Voltage Input Range and Converted Values......................................................................6 - 2
6-2 Current Input Range and Converted Values......................................................................6 - 5
7-1 Specifications of I/O Data....................................................................................................7 - 2
Allocatable I/O Data ..................................................................................................................7 - 2
Data Details...............................................................................................................................7 - 6
Precautions for the I/O Data Size............................................................................................7 - 12
7-2 Setting I/O Allocations with the Sysmac Studio .............................................................7 - 14
Displaying the Edit I/O Allocation Settings Window ................................................................7 - 14
Displayed I/O Allocation Settings ............................................................................................7 - 16
Configuring the I/O Allocation Settings ...................................................................................7 - 18
7-3 List of Settings ...................................................................................................................7 - 20
8-1 Function Block Diagram......................................................................................................8 - 3
8-2 Selecting Channel To Use ...................................................................................................8 - 4
Function Applications and Overview .........................................................................................8 - 4
Details on the Function .............................................................................................................8 - 4
Setting Method ..........................................................................................................................8 - 5
8-3 Input Range Selection .........................................................................................................8 - 6
Function Applications and Overview .........................................................................................8 - 6
Details on the Function .............................................................................................................8 - 6
Setting Method ..........................................................................................................................8 - 6
Function Applications and Overview .........................................................................................8 - 8
Details on the Function .............................................................................................................8 - 8
Setting Method ........................................................................................................................8 - 11
Checking the Sampling Settings .............................................................................................8 - 11
8-5 Digital Filtering...................................................................................................................8 - 18
Function Applications and Overview .......................................................................................8 - 18
Details on the Function ...........................................................................................................8 - 18
Setting Method ........................................................................................................................8 - 27
Checking the Digital Filter Settings .........................................................................................8 - 28
8-6 Input Disconnection Detection .........................................................................................8 - 29
Function Applications and Overview .......................................................................................8 - 29
Details on the Function ...........................................................................................................8 - 29
Setting Method ........................................................................................................................8 - 30
8-7 Over Range/Under Range Detection ................................................................................8 - 31
Function Applications and Overview .......................................................................................8 - 31
Details on the Function ...........................................................................................................8 - 31
Setting Method ........................................................................................................................8 - 32
8-8 User Calibration .................................................................................................................8 - 33
Function Applications and Overview .......................................................................................8 - 33
Details on the Function ...........................................................................................................8 - 33
Setting Method ........................................................................................................................8 - 34
8-9 Zero Set/Reset....................................................................................................................8 - 38
CONTENTS
5