157
Programming Example
Section 7-3
2.
Input the normally closed AND condition T002.
(It isn’t necessary to input leading zeroes.)
3.
Input the 1-second timer T001.
4.
Input the SV for T001 (#0010 = 1.0 s).
(3) Inputting the Two-
second Timer
The following key operations are used to input the 2-second timer.
1,2,3...
1.
Input the normally open condition IR 20000.
2.
Input the normally closed AND condition T002.
(It isn’t necessary to input leading zeroes.)
3.
Input the 2-second timer T002.
4.
Input the SV for T002 (#0020 = 2.0 s).
AND
NOT
TIM
C
2
00005
AND NOT TIM 002
WRITE
00006READ
NOP (000)
TIM
B
1
00006
TIM 001
WRITE
00006 TIM DATA
#0000
B
1
A
0
00006 TIM DATA
#0010
WRITE
00007READ
NOP (000)
LD
C
2
A
0
A
0
A
0
A
0
00007
LD 20000
WRITE
00008READ
NOP (000)
AND
NOT
TIM
C
2
00008
AND NOT TIM 002
WRITE
00009READ
NOP (000)
TIM
C
2
00009
TIM 002
WRITE
00009 TIM DATA
#0000
C
2
A
0
00009 TIM DATA
#0020
WRITE
00010READ
NOP (000)