Specifications of Expansion I/O Units and Expansion Units
Expandable CPU Units
•
Expansion I/O Units and Expansion Units cannot be connected to E10/14/20 or N14/20 CPU Units.
•
A total of up to three Expansion I/O Units and Expansion Units can be connected to an E30/40, N30/40/60 or NA20 CPU Unit.
●
CP1E E10/14/20 or N14/20 CPU Unit
●
CP1E E30/40, N30/40/60 or NA20 CPU Unit
Connection Methods
Connection cables for the Expansion I/O Units and Expansion Units are used to connect the Units. The length can be extended by using a CP1W-
CN811 I/O Connection Cable (length: 800 m).
Maximum Number of I/O Points for an Expanded System
Restrictions on External Power Supply Capacity
The following restrictions apply when using the CPU Unit’s external power supply.
●
AC-power-supply E30/40, N30/40/60 or NA20 CPU Unit
The power supply capacity is restricted for AC-power-supply E30/40, N30/40/60 or NA20 CPU Units. It may not be possible to use the full 300 mA
of the external power supply, though a CPU Unit can connect any CP-series Expansion I/O Unit or Expansion Unit.
The entire 300 mA from the external power supply can be used if Expansion Units and Expansion I/O Units are not connected.
Refer to the CP1E CPU Unit Hardware Manual (Cat. No. W479) for details.
●
AC-power-supply or DC-power-supply E10/14/20, N14/20 CPU Unit
There is no external power supply on AC-power-supply or DC-power-supply E10/14/20, N14/20 CPU Units.
CPU Unit
Built-in I/O on CPU Unit
Built-in Analog
Total number of
Expansion I/O Units and
Expansion Units that can
be connected
Number of inputs: 24
Number of outputs: 16
Total number of I/O points when three CP1W-40ED
@
Expansion I/O Units are connected
Total
Number of
inputs
Number of
outputs
AD
DA
Total
Number of
inputs
Number of
outputs
CP1E-E10D
@
-
@
10
6
4
None
None
Not possible.
10
6
4
CP1E-
@
14D
@
-
@
14
8
6
14
8
6
CP1E-
@
20D
@
-
@
20
12
8
20
12
8
CP1E-
@
30D
@
-
@
30
18
12
3 Units maximum
150
90
60
CP1E-
@
40D
@
-
@
40
24
16
160
96
64
CP1E-N60D
@
-
@
60
36
24
180
108
72
CP1E-NA20D
@
-
@
20
12
8
2
1
140
84
56
CP-series Expansion Units and Expansion I/O
Units cannot be connected.
A total of up to three CP-series Expansion I/O Units
and Expansion Units can be connected.
CH
NC
NC
NC
NC
NC
NC
COM
COM
COM
COM
COM
COM
COM
03
06
01
03
06
00
02
04
06
08
10
00
01
02
04
05
07
00
02
04
05
07
00
02
04
06
08
10
01
03
05
07
09
11
01
03
05
07
09
11
IN
40EDR
OUT
CH
CH
CH
CH
EXP
CH
CH
CH
11
10
09
08
07
06
05
04
03
02
01
00
11
10
09
08
07
06
05
04
03
02
01
00
07
06
05
04
03
02
01
00
07
06
05
04
03
02
01
00
CH
NC
NC
NC
NC
NC
NC
COM
COM
COM
COM
COM
COM
COM
03
06
01
03
06
00
02
04
06
08
10
00
01
02
04
05
07
00
02
04
05
07
00
02
04
06
08
10
01
03
05
07
09
11
01
03
05
07
09
11
IN
40EDR
OUT
CH
CH
CH
CH
EXP
CH
CH
CH
11
10
09
08
07
06
05
04
03
02
01
00
11
10
09
08
07
06
05
04
03
02
01
00
07
06
05
04
03
02
01
00
07
06
05
04
03
02
01
00
CH
NC
NC
NC
NC
NC
NC
COM
COM
COM
COM
COM
COM
COM
03
06
01
03
06
00
02
04
06
08
10
00
01
02
04
05
07
00
02
04
05
07
00
02
04
06
08
10
01
03
05
07
09
11
01
03
05
07
09
11
IN
40EDR
OUT
CH
CH
CH
CH
EXP
CH
CH
CH
11
10
09
08
07
06
05
04
03
02
01
00
11
10
09
08
07
06
05
04
03
02
01
00
07
06
05
04
03
02
01
00
07
06
05
04
03
02
01
00
Summary of Contents for SYSMAC CP1E-E10DR-A
Page 42: ...MEMO 42...