![background image](http://html1.mh-extra.com/html/omron/sysmac-c200h-nc112/sysmac-c200h-nc112_operation-manual_742431083.webp)
75
In this example, DIP switch pin 3 is ON and 8 is OFF. (Refer to
Section 2–1.)
The origin proximity signal and origin signal each occur once.
Origin proximity
signal
Origin signal
Pulse output
1
0
1
0
CCW
CCW
CCW
ORIGIN SEARCH
(Start)
Origin (Stop)
CW limit (0.5 s pause)
Positioning axis
CW
CW
CW
ORIGIN SEARCH
(Start)
Origin (Stop)
ORIGIN SEARCH (Start)
Origin (Stop)
Example 2:
When Origin Proximity
Reverse is Disabled
ORIGIN SEARCH