![background image](http://html1.mh-extra.com/html/omron/sysmac-c200h-nc112/sysmac-c200h-nc112_operation-manual_742431091.webp)
83
In this example, origin proximity reverse is not used. DIP switch pin 3 is ON
and pin 8 is OFF. The origin adjustment command is output after deceleration
has ended.
Origin
proximity
signal
Origin
adjustment
signal
Positioning
completed
signal
Pulse output
Busy flag
1
0
1
0
1
0
Start
Stop
Time
1
0
If the Z-phase signal is input from the encoder during deceleration, the point
at which positioning is stopped differs depending on the length of the deceler-
ation period.
For details on calculating the number of pulses during deceleration, refer to
Mode 1, Example 2: When Origin Proximity Reverse is Disabled.
Example 2:
When Origin Proximity
Reverse is Disabled
ORIGIN SEARCH