background image

K3NC

K3NC

15

Installation

 Example of Connection to Programmable Controller

24 VDC

2. 1

3. 2

4. 4

5. 8

30. RESET

31. POLARITY

26. REQUEST

25. COMMON

24. RUN

1. COMMON

10

0

IN

COM

IN

IN

IN

IN

IN

240 

240 

240 

240 

+5 V

+24 V

0 V

OUT

OUT

COM
(0 V)

Intelligent Signal Processor

PC (SYSMAC)
DC Input Unit

Transistor Output Unit

DC power supply

Internal circuit

Internal circuit

Internal circuit

23. DATA VALID

(Polarity: +, –)

Summary of Contents for Supergate 8615

Page 1: ...available Compact 1 8 DIN size Conforms to EMC standards EN61010 1 IEC1010 1 UL CSA approved uC Ordering Information Base Unit Input type NPN Voltage pulse PNP Supply voltage 100 to 240 VAC 12 to 24...

Page 2: ...s Co u ca o boa ds see note RS 485 K31 FLK2 Yes RS 422 K31 FLK3 Yes Combination output and i ti b d BCD output 5 transistor outputs NPN open collector K31 B4 Yes Yes Co b a o ou pu a d communication b...

Page 3: ...e B4 BCD output 5 transistor outputs NPN open collector L1 Linear output 4 to 20 mA see note L2 Linear output 1 to 5 VDC see note L3 Linear output 1 mV 10 digits see note L4 Linear output 4 to 20 mA 5...

Page 4: ...80 MHz to 1 GHz level 3 10 V m pulse modulated 900 MHz Immunity Conducted Disturbance ENV50141 10 V 0 15 to 80 MHz level 3 Immunity Burst EN61000 4 4 2 kV power line level 3 2 kV I O signal line leve...

Page 5: ...5 FS 1 5 FS Permissible load resistance 600 max 500 min 1 K min Note For the 1 mV 10 digit output the output voltage changes for every 40 to 50 increment in the display value Communications Item RS 23...

Page 6: ...1 2 100 ms max bank switching time Up to 4 set value or prescale value banks available Other functions Variable linear output range for models with linear outputs only Remote Local processing availab...

Page 7: ...e RUN mode from the Setting Protect or Maintenance mode 6 Mode Key Used to enter the Setting mode Used to allow the PV display to indicate set values sequentially Available for Basic Models only Used...

Page 8: ...bank 1 sU1 04 Enter set value OUT4 of bank 1 sU1 05 Enter set value OUT5 of bank 1 Note The above is an example when the bank number is set to 1 pscl Display prescaling p bank Select bank no of presca...

Page 9: ...convert the counting val ue of the K3NC into an appropriate value For example the system shown in the illustration outputs 250 pulses when the object is advanced 0 5 m To enable the K3NC to display j...

Page 10: ...counting inputs are accepted when a RESET input is ON RESET is lit when a RESET input is ON Note External reset minimum signal width 16 ms COMPENSATION Resets the present counting value to the compen...

Page 11: ...OUT1 COM L1 L4 4 to 20 mA L2 L5 1 to 5 V L3 L6 1 mV 10 digit L7 L9 0 to 5 VDC L8 L10 0 to 10 VDC 2 4 8 1 2 4 8 1 2 4 8 1 2 4 8 1 2 18 19 20 21 22 23 24 25 26 K31 FLK1 RS 232C TXD RXD SG K31 FLK2 FLK5...

Page 12: ...s the data will go OFF Models with a BCD output have an open collector output configuration so that wired OR connection is possible The period between the DATA VALID signal and the REQ signal should b...

Page 13: ...ding on the setting conditions the compensation value will be effective only for the incrementing operation Output Delay Reference Value The following table shows the time required for a K3NC in a sys...

Page 14: ...izing circuit Voltage stabilizing circuit Key switch LED Output circuit 8 bit microcomputer Frequency measurement circuit Power supply for sensor input circuit Frequency measurement circuit Waveform a...

Page 15: ...8 30 RESET 31 POLARITY 26 REQUEST 25 COMMON 24 RUN 1 COMMON 100 IN COM IN IN IN IN IN 240 240 240 240 5 V 24 V 0 V OUT OUT COM 0 V Intelligent Signal Processor PC SYSMAC DC Input Unit Transistor Outpu...

Page 16: ...severe shock or vibration excessive dust or excessive moisture Select an indoor mounting location where the Intelligent Signal Pro cessor is at the rated temperature and humidity and free from direct...