K3NC
K3NC
9
Parameters
Linear Output Range
lset
A linear output range can be set as required. A value corresponding
to the maximum output value and that corresponding to the mini-
mum output value can be set.
Display
20 mA
4 mA
Upper
limit
Output
Lower
limit
For the 4- to 20-mA
output type
Remote/Local Selection
rl
Select remote programming when performing all settings through
the host devices and select local programming when performing
settings through key operation.
Prescaling
The prescale function makes it possible to convert the counting val-
ue of the K3NC into an appropriate value.
For example, the system shown in the illustration outputs 250
pulses when the object is advanced 0.5 m. To enable the K3NC to
display
jjjj
.
j
(mm), obtain the advanced length of the object
per pulse from the following formula.
500 mm (0.5 m)/250 = 2
1. The prescale value is set by the mantissa X multiplied by the
exponent Y as follows:
Prescale value = 2.0000 x 10
0
X = 2.0000, Y = 00
2. Set the decimal point to the left of the rightmost digit.
0.5 m
250
pulses
Encoder
K3NC
Terminal Arrangement
18 19
20
21 22
23
24 25
26
10
11
12
13
14
15
16
17
1
2
3
4
5
6
7
8
9
Terminal Numbers
Note:
Terminals 7 to 13 are connected internally.
Output
unit
Input
unit
Output unit
Input unit