Operation
Setting Procedures
The K3NC has four modes: RUN mode for normal operations, Setting mode for initial parameter input, Protect mode for lock-out configuration,
and Maintenance mode for initializing set values. The parameters that are accessible on any individual K3NC will vary depending on the Output
Board installed. Refer to the
K3NC Operation Manual for details.
RUN Mode:
Remains in this mode under normal operation.
The process value can be monitored.
Using the front panel keys, the comparative set value can be changed and counting value reset can be performed.
Setting Mode:
Used for making initial settings.
Includes settings for four menus (Set value (
sUset
), prescaling (
pscl
), setup (
setup
), option (
opt
)) and the output test.
Protect Mode:
Used for locking the front key operation or parameter changes.
Maintenance Mode:
Used for initializing set values.
Power ON
RUN mode
Setting mode
Maintenance mode
Protect mode
1 s
1 s
+
+
ESC
ESC
ESC
ESC
When power is ON
sUset
- Program set values
s.bank
Select bank no. of set values
sU1.01
Enter set value OUT1 of bank 1
sU1.02
Enter set value OUT2 of bank 1
sU1.03
Enter set value OUT3 of bank 1
sU1.04
Enter set value OUT4 of bank 1
sU1.05
Enter set value OUT5 of bank 1
Note:
The above is an example when the bank number is set to 1.
pscl
- Display prescaling
p.bank
Select bank no. of prescale values
ps1.ax
Set the mantissa (X) of the prescale value
ps1.ay
Set the exponent (Y) of the prescale value
decp.1
Select decimal point
Note:
The above is an example when the bank number is set to 1.
prot
- Program lock-out configuration
all
Enable all key protection
sUset
Enable set value change prohibition
reset
Enable prohibition of counting value reset using
the front panel keys
secr
Specify the menus to be protected against set-
ting in the setting mode
setup
- Program input mode/input sensor/serial communications
count
Specify input mode
in
Select a sensor type
uno
Enter the unit no. for the host
bps
Select the baud rate
len
Select the word bit length
sbit
Select the stop bits
prty
Select the parity bits
opt
- Supplementary settings related to display or control
memo
Select power failure memory function
compn
Set compensation value
conp
Select conditions that allow compensation input
out
Select output mode
lset.h
Enter the upper limit (H) of linear output range
lset.l
Enter the lower limit (L) of linear output range
rl
Select the remote/local programming
test
- Generating simulated input for testing the output function