![background image](http://html1.mh-extra.com/html/omron/supergate-8615/supergate-8615_quick-start-manual_743387010.webp)
K3NC
K3NC
10
Input Board
Note:
Terminals 7 and 13 are insulated
from each other.
Power supply
12 VDC
(80 mA max.)
Signal input terminals
K3NC-NB
(NPN input/voltage pulse input)
K3NC-PB (PNP input)
+12 V
Contact
NPN output sensor
Voltage output
PNP output sensor
+12 V
0 V
0 V
+12 V
0 V
Rotary Encoder Connection Example
0 V
Phase A
Phase B
INA/INB
Counts input signals.
Accepts Up/Down (individual or phase difference) inputs.
RESET
Resets the present value to zero.
No counting inputs are accepted when a RESET input is ON.
RESET is lit when a RESET input is ON.
Note:
External reset minimum signal width: 16 ms
COMPENSATION
Resets the present counting value to the compensation value at the rising edge of a compensation input.
In the compensation value setting parameter, it is possible to set to “Effective during incrementing and
decrementing a count” or to “Effective only during incrementing a count.”
Note:
External compensation input minimum signal width: 16 ms
BANK 1, 2
Selects one of the four banks.
Bank no.
Control input
Bank 1
Bank 2
1
OFF
OFF
2
ON
OFF
3
OFF
ON
4
ON
ON
Note:
Bank switching minimum signal width: 100 ms max.