background image

K3NC

K3NC

4

Specifications

 Ratings

Supply voltage

100 to 240 VAC (50/60 Hz); 12 to 24 VDC

Operating voltage range

85% to 110% of supply voltage

Power consumption (see note)

15 VA max. (max. AC load with all indicators lit)
10 W max. (max. DC load with all indicators lit)

Sensor power supply

80 mA at 12 VDC

±

10%

Insulation resistance

20 M

 min. (at 500 VDC) between external terminal and case.

Insulation provided between inputs, outputs, and power supply.

Dielectric withstand voltage

2,000 VAC for 1 min between external terminal and case.
Insulation provided between inputs, outputs, and power supply.

Noise immunity

±

1,500 V on power supply terminals in normal or common mode 

±

µ

s, 100 ns for

square-wave noise with 1 ns

Vibration resistance

Malfunction: 10 to 55 Hz, 0.5-mm for 10 min each in X, Y, and Z directions
Destruction: 10 to 55 Hz, 0.75-mm for 2 hrs each in X, Y, and Z directions

Shock resistance

Malfunction: 98 m/s

2

 (10G) for 3 times each in X, Y, and Z directions

Destruction: 294 m/s

2

 (30G) for 3 times each in X, Y, and Z directions

Ambient temperature

Operating: –10

°

C to 55

°

C (with no icing)

Storage:

–20

°

C to 65

°

C (with no icing)

Ambient humidity

Operating: 25% to 85% (with no condensation)

Ambient atmosphere

Must be free of corrosive gas

EMC

Emission Enclosure:

EN55011 Group 1 class A

Emission AC Mains:

EN55011 Group 1 class A

Immunity ESD:

EN61000-4-2:4-kV contact discharge (level 2)

8-kV air discharge (level 3)

Immunity-RF-interference:

ENV50140:

10 V/m (amplitude modulated, 80 MHz to
1 GHz) (level 3)
10 V/m (pulse modulated, 900 MHz)

Immunity Conducted Disturbance:

ENV50141:

10 V (0.15 to 80 MHz) (level 3)

Immunity Burst:

EN61000-4-4:2-kV power-line (level 3)

2-kV I/O signal-line (level 4)

Approved standards

UL508, CSA22.2; conforms to EN50081-2, EN50082-2, EN61010-1 (IEC1010-1); conforms to
VDE106/part 100 (Finger Protection) when the terminal cover is mounted.

Weight

Approx. 400 g

Note:

An Intelligent Signal Processor with DC supply voltage requires approximately 1 A DC as control power supply current the moment the
Intelligent Signal Processor is turned on. Do not forget to take this into consideration when using several Intelligent Signal Processors.
When the Intelligent Signal Processor is not in measuring operation (e.g., the Intelligent Signal Processor has been just turned on or is
operating for startup compensation time), the display will read “

00000

” and all outputs will be OFF.

Input/Output Ratings

Relay Contact Output

(Incorporating a G6B Relay)

Item

Resistive load (cos

φ

 = 1)

Inductive load (cos

φ

 = 0.4, L/R = 7 ms)

Rated load

5 A at 250 VAC; 5 A at 30 VDC

1.5 A at 250 VAC, 1.5 A at 30 VDC

Rated carry current

5 A max. (at COM terminal)

Max. contact voltage

380 VAC, 125 VDC

Max. contact current

5 A max. (at COM terminal)

Max. switching capacity

1,250 VA, 150 W

375 VA, 80 W

Min. permissible load 
(P level, reference value)

10 mA at 5 VDC

Mechanical life

50,000,000 times min. (at a switching frequency of 18,000 times/hr)

Electrical life 
(at an ambient temperature of 23

°

C)

100,000 times min. (at a rated load switching frequency of 1,800 times/hr)

Transistor Output

Rated load voltage

12 to 24 VDC 

+10%

/

–15%

Max. load current

50 mA

Leakage current

100 

µ

A max.

Summary of Contents for Supergate 8615

Page 1: ...available Compact 1 8 DIN size Conforms to EMC standards EN61010 1 IEC1010 1 UL CSA approved uC Ordering Information Base Unit Input type NPN Voltage pulse PNP Supply voltage 100 to 240 VAC 12 to 24...

Page 2: ...s Co u ca o boa ds see note RS 485 K31 FLK2 Yes RS 422 K31 FLK3 Yes Combination output and i ti b d BCD output 5 transistor outputs NPN open collector K31 B4 Yes Yes Co b a o ou pu a d communication b...

Page 3: ...e B4 BCD output 5 transistor outputs NPN open collector L1 Linear output 4 to 20 mA see note L2 Linear output 1 to 5 VDC see note L3 Linear output 1 mV 10 digits see note L4 Linear output 4 to 20 mA 5...

Page 4: ...80 MHz to 1 GHz level 3 10 V m pulse modulated 900 MHz Immunity Conducted Disturbance ENV50141 10 V 0 15 to 80 MHz level 3 Immunity Burst EN61000 4 4 2 kV power line level 3 2 kV I O signal line leve...

Page 5: ...5 FS 1 5 FS Permissible load resistance 600 max 500 min 1 K min Note For the 1 mV 10 digit output the output voltage changes for every 40 to 50 increment in the display value Communications Item RS 23...

Page 6: ...1 2 100 ms max bank switching time Up to 4 set value or prescale value banks available Other functions Variable linear output range for models with linear outputs only Remote Local processing availab...

Page 7: ...e RUN mode from the Setting Protect or Maintenance mode 6 Mode Key Used to enter the Setting mode Used to allow the PV display to indicate set values sequentially Available for Basic Models only Used...

Page 8: ...bank 1 sU1 04 Enter set value OUT4 of bank 1 sU1 05 Enter set value OUT5 of bank 1 Note The above is an example when the bank number is set to 1 pscl Display prescaling p bank Select bank no of presca...

Page 9: ...convert the counting val ue of the K3NC into an appropriate value For example the system shown in the illustration outputs 250 pulses when the object is advanced 0 5 m To enable the K3NC to display j...

Page 10: ...counting inputs are accepted when a RESET input is ON RESET is lit when a RESET input is ON Note External reset minimum signal width 16 ms COMPENSATION Resets the present counting value to the compen...

Page 11: ...OUT1 COM L1 L4 4 to 20 mA L2 L5 1 to 5 V L3 L6 1 mV 10 digit L7 L9 0 to 5 VDC L8 L10 0 to 10 VDC 2 4 8 1 2 4 8 1 2 4 8 1 2 4 8 1 2 18 19 20 21 22 23 24 25 26 K31 FLK1 RS 232C TXD RXD SG K31 FLK2 FLK5...

Page 12: ...s the data will go OFF Models with a BCD output have an open collector output configuration so that wired OR connection is possible The period between the DATA VALID signal and the REQ signal should b...

Page 13: ...ding on the setting conditions the compensation value will be effective only for the incrementing operation Output Delay Reference Value The following table shows the time required for a K3NC in a sys...

Page 14: ...izing circuit Voltage stabilizing circuit Key switch LED Output circuit 8 bit microcomputer Frequency measurement circuit Power supply for sensor input circuit Frequency measurement circuit Waveform a...

Page 15: ...8 30 RESET 31 POLARITY 26 REQUEST 25 COMMON 24 RUN 1 COMMON 100 IN COM IN IN IN IN IN 240 240 240 240 5 V 24 V 0 V OUT OUT COM 0 V Intelligent Signal Processor PC SYSMAC DC Input Unit Transistor Outpu...

Page 16: ...severe shock or vibration excessive dust or excessive moisture Select an indoor mounting location where the Intelligent Signal Pro cessor is at the rated temperature and humidity and free from direct...