![background image](http://html1.mh-extra.com/html/omron/stc-hd213-series/stc-hd213-series_product-specifications-and-users-manual_742895069.webp)
No. 20S071-01
STC-HD213DV / STC-HD213DV-CS / STC-HD213SDI / STC-HD213SDI-CS /
STC-HD213DVN / STC-HD213DVN-CS / STC-HD213SDIN / STC-HD213SDIN-CS
Product Specifications and User’s Guide
69/94
Slave address for ICs (8bits) list
IC
Slave Address
詳細
DSP
82
DSP data
EEPROM
62
The Virtual EEPROM zone for currently selected DSP preset
mode of Preset 0 to Preset 7
EEPROM
90
The EEPROM zone for Preset 0 DSP data
EEPROM
91
The EEPROM zone for Preset 1 DSP data
EEPROM
92
The EEPROM zone for Preset 2 DSP data
EEPROM
93
The EEPROM zone for Preset 3 DSP data
EEPROM
94
The EEPROM zone for Preset 4 DSP data
EEPROM
95
The EEPROM zone for Preset 5 DSP data
EEPROM
96
The EEPROM zone for Preset 6 DSP data
EEPROM
97
The EEPROM zone for Preset 7 DSP data
uCOM
22
The uCOM data
EEPROM
42
The EEPROM zone for uCOM Data
Note: There is maximum number of writing to EEPROM of 1,000,000 times.
Error code list
If an error occurs, camera sends an error code with following format:
The Command number of Error Message is FF (HEX). The Data length is 0002.
Error
Receive data
Last data that camera was received was not ETX (0x03)
02, FF, 00, 02, 02, 00, 03, 03
Check sum does NOT match data being transmitted
02, FF, 00, 02, 03, 00, 04, 03
The command being transmitted does NOT exist or is invalid
02, FF, 00, 02, 04, 00, 05, 03
Unprocessed data remains in receiving buffer
02, FF, 00, 02, 05, 00, 06, 03
Time out
02, FF, 00, 02, 06, 00, 07, 03
Over run error
02, FF, 00, 02, 08, 00, 08, 03
Data length error (too long)
02, FF, 00, 02, 0B, 00, 0C, 03
I2C communication error
02, FF, 00, 02, 10, 00, 11, 03
Note.1: The camera disregards data, which is not start with STX (0x02).
Note.2: The time out error is occurred when camera does not receive next data 3 seconds after receiving
data.