No. 20S071-01
STC-HD213DV / STC-HD213DV-CS / STC-HD213SDI / STC-HD213SDI-CS /
STC-HD213DVN / STC-HD213DVN-CS / STC-HD213SDIN / STC-HD213SDIN-CS
Product Specifications and User’s Guide
70/94
8.4 The uCOM register mapping list
* Please do not change “Reserved data”.
Address 7 6 5 4 3 2 1 0 Descriptions
Default
000
X X X User Preset
DSP register setting can save on eight Preset areas.
* When this vale saves to EEPRM, camera starts with saved DSP
mode at power up.
0: Preset 0
1: Preset 1
2: Preset 2
3: Preset 3
4: Preset 4
5: Preset 5
6: Preset 6
7: Preset 7
0
X X X X X
Reserved
-
001 -
00D
X X X X X X X X Reserved
-
00E
X "Push button" function
0: Disable
1: Enable
1
X X X X X X X
Reserved
-
00F
X X X UART baud rate
0: 9,600 bps
1: 19,200 bps
2: 38,400 bps
3: 57,000 bps
4: 115,200 bps
* Change to lower baud rate when communication error is
occurred.
2
X X X
Reserved
-
X
Return data and data length of UART write command
0: Disable.
Return data is including exact same data of write command.
1: Enable.
Return data is excluding data of write command, and data
length is 0.
0
X
UART check sum
0: Disable
1: Enable
* When selecting disable, camera process command even check
sum of send command is not mach.
1