No. 20S071-01
STC-HD213DV / STC-HD213DV-CS / STC-HD213SDI / STC-HD213SDI-CS /
STC-HD213DVN / STC-HD213DVN-CS / STC-HD213SDIN / STC-HD213SDIN-CS
Product Specifications and User’s Guide
42/94
1) R gain and B gain reference level of low color temperature
Sets the R and B gain reference level for low color temperature of AWB control.
2) R gain and B gain reference level of middle color temperature
Sets the R and B gain reference level for middle color temperature of AWB control.
3) R gain and B gain reference level of high color temperature
Sets the R and B gain reference level for high color temperature of AWB control.
4) R gain frame and B frame for low color temperature
Sets the tolerance area (+ and - frame) of R and B gain for low color temperature of AWB control.
5) R gain frame and B frame for low color temperature
Sets the tolerance area (+ and - frame) of R and B gain for middle color temperature of AWB control.
6) R gain frame and B frame for low color temperature
Sets the tolerance area (+ and - frame) of R and B gain for high color temperature of AWB control.
7) AWB tolerance (pull-in limit)
The pull-in limit AWB process will be stop when white balance error becomes smaller than AWB tolerance.
8) AWB threshold (pull-in limit)
The pull-in limit AWB process will be start when white balance error becomes greater than “(AWB tol
AWB threshold)”
9) AWB step divisor (pull-in limit)
Sets the step divisor of pull-in AWB process.
1) AWB tolerance (No limited gain)
The no limited gain AWB process will be stop when white balance error becomes smaller than AWB tolerance.
2) AWB threshold (No limited gain)
The no limited gain AWB process will be start when white balance error becomes greater than “(AWB tolerance
+ AWB threshold)”
3) AWB R and B change limit
Sets the control speed for no limit gain AWB process.
The maximum amount of white balance gain change is limit by this setting. (There is no limit when setting “0”)