No.16S058-01
45/49
STC-HD133 Series (STC-HD133DV / STC-HD133SDI) /
STC-HD93 Series (STC-HD93DV / STC-HD93SDI) Users guide
L. uCOM: Other
DSP preset, OSD menu setting, the frame rate of the image selection, the test pattern selection and the
UART settings are changeable in this window.
1) DSP preset selection
The camera has 28 DPS presets.
The settings in “DSP:” started window can be change for each DSP preset.
2) OSD menu
OSD menu setting. (the color of OSD, the size of OSD and OSD start position)
3) FPS selection
The frame rate of the image is selectable from 50Hz, 60Hz and 59.95Hz.
4) Test pattern display
The camera can output the test pattern for the monitor testing.
The test pattern is selectable from “Gray scale”, “Color bar” and “Gray scale and color bar)
5) UART
The communication setting. (UART baud rate, the return data of write command, includes the write data
or not, and the check sum enable/disable)