background image

S8PS

S8PS

9

 DIN Track Mounting Bracket Type

DIN Track Mounting Bracket

DIN Track Mounting Bracket is
attached to the Power Supply
Unit when the Unit is shipped.

S8PS-10024D (100 W)
S8PS-10024CD (100 W)

S8PS-15024D (150 W)
S8PS-15024CD (150 W)

Five, M4 terminal screws

3.5 dia.

11.5 max.

5.6 
(With slide: 9 max.)

Five, M4 terminal screws

4.5 dia.

11.5 max.

5.6 
(With slide: 9 max.)

Five, M4 terminal screws

4.5 dia.

11.5 max.

5.6 
(With slide: 9 max.)

S8PS-050

jj

D (50 W)

S8PS-050

jjj

CD (50 W)

Summary of Contents for S8PS Series

Page 1: ...Power ratings Output voltage Output current Front mounting Bracket DIN Track Mounting Bracket Covered type 100 to 240 VAC 50 W 5 V 10 A S8PS 05005C S8PS 05005CD Co e ed y e 00 o 0 C 50 12 V 4 2 A S8PS...

Page 2: ...s2 approx 30G 3 times each in X Y and Z directions Output indicator Yes green Terminal screw tightening torque 1 08 N S m 11 kgf S cm see note 2 Electromagnetic interference Conforms to FCC Class B E...

Page 3: ...on 600 W Model 20 mm min 20 mm min 20 mm min 20 mm min 30 mm min 30 mm min 20 mm min 20 mm min 30 mm min 30 mm min 20 mm min 20 mm min 20 mm min 20 mm min 20 mm min 20 mm min 50 to 150 W Model Natural...

Page 4: ...ercurrent condition continued otherwise the internal elements of the S8PS may be dam aged or broken Overvoltage Protection The Power Supply is provided with an overvoltage protection func tion that pr...

Page 5: ...hing circuit Detector Control circuit Overload detection circuit Overload detection circuit Harmonic current control Smooth ing Overload detection circuit Overload detection circuit Rectifier smoothin...

Page 6: ...h 6 max Front mounting Bracket for 50 W Models Mounting Holes Using the Mounting Bracket Attach the Mounting Bracket to the panel and loosely tighten the two screws Insert the projected parts of the B...

Page 7: ...ounting Bracket for 100 150 W Models Dimensions with Mounting Bracket Using the Mounting Bracket S8PS 30024C 300 W Eight M4 depth 8 max also for the opposite side Mounting holes also on opposite side...

Page 8: ...our M4 depth 8 max 300 W models 600 W models Four M4 Four M4 10 dia Two 5 dia 600 W models Note Mount the Unit 21 6 mm away from the mounting surface in order to provide air ventilation on the rear si...

Page 9: ...y Unit when the Unit is shipped S8PS 10024D 100 W S8PS 10024CD 100 W S8PS 15024D 150 W S8PS 15024CD 150 W Five M4 terminal screws 3 5 dia 11 5 max 5 6 With slide 9 max Five M4 terminal screws 4 5 dia...

Page 10: ...Order Separately PFP 100N PFP 50N 4 5 15 25 25 25 25 10 10 1 000 500 see note 7 3 0 15 35 0 3 27 0 15 1 4 5 15 25 25 25 25 15 10 10 1 000 35 0 3 27 24 16 29 2 1 1 5 PFP 100N2 15 5 see note Note The va...

Page 11: ...been turned OFF Doing so may result in electric shock due to a residual voltage Do not touch the S8PS or heat radiation fin while the power is being supplied or immediately after the power is turned...

Page 12: ...dust As a preventive maintenance measure replace the fan within two years if it is used at an ambient temperature of 40 C Fans are available as replacements Model S82Y JFAN Fan Set Fan above four M4 x...

Reviews: