Parallel Operation
Only 300- and 600-W models can be in parallel operation provided
that they are operated under 90% of the ratings. Do not operate any
other models in parallel.
Make sure that the thickness and the length of all wires connected to
the load are the same to ensure that the wires will have no voltage
drop differences.
INPUT
+ V
– V
+ V
– V
INPUT
Load
Fan Replacement
The service life of the fan is approximately 50,000 hours (at 25
°
C).
The service life varies, however, depending on the ambient temper-
ature or other surrounding environmental conditions such as dust.
As a preventive maintenance measure, replace the fan within two
years if it is used at an ambient temperature of 40
°
C.
Fans are available as replacements.
Model: S82Y-JFAN
Fan Set:
Fan (above), four M4 x 35 sems screws, instruction sheet, and
packing case
Replace the fan as shown in the following illustration.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.