106
Echoback Test
Section 6-7
6-7
Echoback Test
This service performs an echoback test.
■
Service Request PDU
■
Service Response PDU
(1) Test Data
Set values for the test data within the ranges shown below, depending on
the communications data length setting.
(2) Response Codes
MRC SRC
0 8 0 1
2 2
Test Data
0 to 231
MRC SRC
0 8 0 1
2 2
4
Response Code
Test Data
0 to 231
Data length
Processing
8 bits
ASCII data: 20 to 7E or A1 to FE
7 bits
ASCII data: 20 to 7E
Response
code
Error name
Cause
Error
priority
1001
Command too long
The command is too long.
1
0000
Normal completion
No error
0