3 Configuration Units
3 - 16
NX-series CPU Unit Hardware User’s Manual (W535)
With an NJ/NX-series CPU Unit, you can connect the Sysmac Studio online in the following ways.
Connection with EtherNet/IP
3-4-2
Connection
Configuration
• 1:1 Connection
• 1:N Connection
• A direct connection is made from the
Sysmac Studio. The IP address and
connection device do not need to be
specified.
*1
• You can make the connection
whether or not a switching hub is
used.
• Support for Auto-MDI enables the use
of cross cables or straight cables if a
direct connection is made.
*1. With the NX7-series CPU Unit, it is possible only when you connect the Unit to the built-in EtherNet/IP port (port
1).
Directly specify the IP address of the remote device.
EtherNet/IP
Sysmac Studio
EtherNet/IP
Sysmac Studio