NV-series PT Simple Operation Handbook
Advanced UsageAdvanced Usage
Ct
i
it
h
Connecti
n
g w
ith
CPIE PLC
Designing Screens
Preparation
11
4.
Select
Options – Transfer to PLC
from the menu bar.
Click!!
* It is not selectable, when the PLC
operation mode is not in Program
Mode.
1) Do not select.
2) Click the
Yes
Button.
2. The
PLC Settings
Dialog Box appears .
Select
Options – Transfer from PLC
from the menu bar.
* The second value from the
left of Format is the stop bit.
Be sure to set it to “1” when
the PLC is connected to an
NV.
Click!!
Click!!
3.
The PLC settings for the CP1E are uploaded to the PC. Make the setting on the
Built-in
RS232C Port
Tab Page as follows.
Turning OFF and then ON the power of the CP1E
1. Turn OFF and then ON the power of the CP1E. The RS-232C serial port setting becomes
effective when the power is turned ON. This completes the CP1E communications setting.