7
.
EtherNet/IP Connection Procedure
31
5
In the same way as steps 3 and
4, enter the following data in the
newly added row.
・
Name:
W
Data type:
DWORD
6
Click the
Structures
Side Tab.
Click on a space in the
Name
Column to enter a new data
type.
Enter
S_EIPOutput
in the
Name
Column.
7
After entering, right-click and
select
Create New Member
from the menu.
8
Enter
SensorHeadControlFlag1
in the
Name
Column.
Enter
U_EIPFlag
in the
Base
Type
Column.
9
In the same way as steps 7 and
8, enter the following data in the
newly added rows.
・
Name:
SensorHeadControlFlag2
Base type:
U_EIPFlag
・
Name:
SensorHeadControlReserve
Base type:
U_EIPFlag
・
Name:
CommandCode
Base type:
DWORD
・
Name:
CommandParam1
Base type:
UINT
・
Name:
CommandParam2
Base type:
UINT
・
Name:
CommandParam3
Base type:
DINT
*Enter each member of the data
type in order from the top of the
list described in
6.2. Data Types
to Use for Tag Data Links
.