6
.
EtherNet/IP Settings
13
*2: Assignment of Sensor Head status signal2
Variable: EIPInput.SensorHeadStatusFlag2.F
15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
TASK
STAT
_T4
TASK
STAT
_T3
TASK
STAT
_T2
TASK
STAT
_T1
OR
GATE ENABLE
STABIL
ITY1
LIGHT
RESET
STAT
HOLD
STAT
31 30 29 28 27 26 25 24 23 22 21 20
19
18
17
16
LOW
_T4
PASS
_T4
HIGH
_T4
LOW
_T3
PASS
_T3
HIGH
_T3
LOW
_T2
PASS
_T2
HIGH
_T2
LOW
_T1
PASS
_T1
HIGH
_T1
ZERO
STAT_
T4
ZERO
STAT_
T3
ZERO
STAT_
T2
ZERO
STAT_
T1
HOSDSTAT
: Hold execution status
RESETSTAT
: Reset execution state
LIGHT
: Logical beam lighting state
STABILITY1
: Measurement position
ENABLE
: Measurement state
GATE
: Data output completed
OR
: Overall judgment result
TASKSTAT_Tn : TASK n TASK status (n: 1 to 4)
ZEROSTAT_Tn : TASK n Zero reset state (n: 1 to 4)
HIGH_Tn
: TASK n HIGH output (n: 1 to 4)
PASS_Tn
: TASK n PASS output (n: 1 to 4)
LOW_Tn
: TASK n LOW output (n: 1 to 4)
Additional Information
For details on command and response codes, refer to
Memory Assignments and Commands
in
4-1 EtherNet/IP Connection
of the
Displacement Sensor ZW-7000 series Confocal Fiber
Type Displacement Sensor User’s Manual for Communications Settings
(Cat. No. Z363).
Summary of Contents for NJ501-1500