background image

Motion controller

69

Motion control function specifications

MP2300 CPU (basic module)

Item

Specifications

Interface

MECHATROLINK-I, MECHATROLINK-II

Number of controlled axes/module

Up to 16 axes

Control 
specifications

PTP control

Linear, rotary, and infinite-length

Interpolation

Up to 16 linear axes, 2 circular axes, and 3 helical axes

Speed reference output

Yes

Torque reference output

Yes

Phase control

Yes

Position 
control

Positioning

Yes

External positioning

Yes

Zero point return

Yes

Interpolation

Yes

Interpolation with position 
detection function

Yes

JOG operation

Yes

STEP operation

Yes

Parameter changes during 
motion command execution

Yes

Reference unit

mm, inch, deg, or pulse

Reference unit minimum setting

1, 0.1, 0.01, 0.001, 0.0001, 0.00001

Maximum programmable value

-2147483648 to +2147483647 (signed 32-bit value)

Speed reference unit

Reference unit/s designation: mm/s, inch/s, deg/s, pulse/s
Reference unit/min. designation: mm/min, inch/ min, deg/min, pulse/min
Percentage designation: Percentage of rated speed

Acceleration/deceleration type

Linear, asymmetric, S-curve, exponent

Acceleration/deceleration reference unit

Reference unit/s

2

 designation: mm/s

2

, inch/s

2

, deg/s

2

, pulse/s

2

Acceleration/deceleration time constant: Time from 0 to rated speed (ms)

Override function

Positioning: 0.01% to 327.67% by axis 

Coordinate system

Rectangular coordinates

Zero point re-
turn

DEC1+ phase-C pulse 

Yes

ZERO signal

Yes

DEC1+ ZERO signal

Yes

Phase-C pulse

Yes

Only phase-C pulse

Yes

POT and 

phase-C pulse

Yes

POT

Yes

Home limit switch and 

phase-C pulse

Yes

HOME

Yes

NOT and 

phase-C pulse

Yes

NOT

Yes

INPUT and 

phase-C pulse

Yes

INPUT

Yes

Applicable servo drives

SGDH-

@@@

E-OY + NS115

Applicable frequency inverters

Varispeed V7, F7, G7 with MECHATROLINK-II interface 
(for inverter version support contact your OMRON sales office)

Encoders

Incremental encoder
Yaskawa absolute encoder

Items

Specifications

Appearance

Model

JEPMC-MP2300

Power supply

Input power voltage: 24 VDC±20%
Current consumption:1 A
Inrush current: 40 A or less

Motion network

One channel for MECHATROLINK-II:
Twenty-one stations, including servo drives and I/O equipment, can be connected. 
(16 axes for servo drives and inverters)
Transmission speed: 10Mbps (MECHATROLINK-II)
Transmission distance: See “MECHATROLINK-II repeater”

I/O signals

Digital input:

8 points (one point can be used for interrupts),
24 VDC, 4 mA, and source mode or sink mode input

Digital output: 4 points, 24 VDC, 100 mA, open collector, and sink mode output (NPN)

Slot for optional modules

3 slots

Dimensions (mm)

130x120x108 (HxWxD)

Weight

500 g

Y203-EN2-02-Katalog.book  Seite 69  Mittwoch, 24. Mai 2006  2:22 14

Summary of Contents for MP2300 MECHATROLINK-II

Page 1: ...6 B C N 4 CHARGE POWER SERVOPACK SGDH 200V Ver CN3 CN1 CN2 NS115 S W 1 S W 2 A R C N 6 A C N 6 B C N 4 CHARGE POWER SERVOPACK SGDH 200V Ver CN3 CN1 CN2 CHARGE POWER SERVOPACK SGDH 200V Ver CN3 CN1 CN2...

Page 2: ...300 ms Integral multiple of MECHATROLINK communication cycle User drawings functions and motion programs Startup drawings DWG A Interrupt processing drawings DWG I High speed scan process drawings DWG...

Page 3: ...pulse s2 Acceleration deceleration time constant Time from 0 to rated speed ms Override function Positioning 0 01 to 327 67 by axis Coordinate system Rectangular coordinates Zero point re turn DEC1 ph...

Page 4: ...or slave MELSEC HostLink or non protocol Max number of words in transmission 512 words 1024 bytes Media access control method 1 1 Communication protocols Extended MEMOBUS MEMOBUS MELSEC A non protocol...

Page 5: ...l resistor JEPMC W6022 required Transmission speed 10 Mbps Communication cycle 0 5ms 1ms 1 5ms 2ms Number of connecting stations 21 stations 16 axes for servo drives and inverters 2 ms 15 stations 15...

Page 6: ...e output NPN Signal connection method Connector FCN360 series Module power supply 24 VDC 20 4 V to 28 8 V Rated current 0 5 A Inrush current 1 A Weight 590 g Items Specifications Appearance Model JEPM...

Page 7: ...put MECHATROLINK I II communications Commands position speed torque parameter read write monitor output Position control functions Acceleration deceleration method Linear first second step asymmetric...

Page 8: ...D6 LD5 LIO 01 10Base T PORT ON OFF TEST INIT TX STRX RUN RX COL ERR 218IF 01 4 tapped holes M4 121 0 2 111 0 2 Mounting hole diagram 108 18 4 5 121 130 4 5 120 4 5 4 5 111 4 tapped holes M4 121 0 2 11...

Page 9: ...t output JEPMC IO2310 Reversible counter 2 channels JEPMC PL2900 Pulse output 2 channels JEPMC PL2910 Analog input 10 V to 10 V 4 channels JEPMC AN2900 Analog output 10 V to 10 V 2 channels JEPMC AN29...

Page 10: ...software to support from system design to maintenance Intuitive ladder programming and editing functions CAM data generation Windows based Windows 95 98 NT4 0 2000 XP CPMC MPE720 In the interest of p...