Blood pressure measurement module M3500

Page 6 of 8

https://translate.googleusercontent.com/translate_c?depth=1&hl=…03%3Fview%3Dbody&usg=ALkJrhhqzooj9yOkvRDfve8nZaQansOoVg#WARNING

1.

2.

If you have pressure on the arms, it was raised tucked clothing 

• If you are using a heart-lung machine (because there is no beat) 

· In the case of pseudo-hypertension

Interaction

- The periphery of the person at the time of defibrillator use please away from the device and the
cords that are connected to the subject and the subject. We received a blitz by energization
energy of the defibrillator.

Or - at the time of defibrillator use is energized as much as possible away from the electrodes
attached to the chest, please instead of attaching the electrodes to the appropriate position. 
When the defibrillator paddles to energize while touching the electrode, it will cause burns to the
site.

And electric knife during use and after use be sure to check the operation of the machine. It may
indicate the measurements wrong by the noise of the electric knife.

- Of the electric knife if attachment of the return electrode is inappropriate, it can cause burns in
the subject mounting portion. Please carefully read the instruction manual of the electric knife
for more information.

Microwave therapy equipment equipment that generates the noise, such as you might not be able
to if measured correctly in the vicinity.

- Such as the commercially available personal computer to the external I / O connector, please do
not direct connection with the equipment that does not meet the medical safety standards
(IEC60601-1 or IEC safety standards). Please connect Ri by the company designation of ways to
connect. If an unspecified connection you may want to shock due to the leakage current.

Other Notes

And non-invasive blood pressure measurement is done by squeezing the arm. 
Or feel a strong pain in some people, it may be transient Madaragami by subcutaneous
hemorrhage. This plaque is Suga disappears over time, the possibility of a person to be measured
to be made in care We tell you that the "Madaragami is there is a Rukoto", you may need to
refrain from the measurement.

Storage and storage method and duration of use, etc.

Storage condition

(1) Please keep to the environment, such as the following. 
** Temperature: -20 ~ 70 

 (standard accessories, optional accessories are excluded) 

Humidity: 30% to 95% (non-condensing)

Life

Six years after installation (self by our data authentication) 

Summary of Contents for M3500

Page 1: ...ressure module Blood pressure measurement module M3500 Be sure to refer to the instruction manual Creation or revision date March 1 2012 third edition October 17 2011 second edition Approval and notification etc Brand Name Blood pressure measurement module M3500 Attached document management code 22200BZX00227000_A_01 Approval Number 22200BZX00227000 Approval date March 2010 General designation for...

Page 2: ...e Magnetic resonance imaging apparatus There is a risk of causing accidents caused by combination induced electromotive force of the MRI devices how to use That you do not use If the exterior of the cuff there is corruption There is a risk of rupture during the measurement Shape and structure and principles etc This unit is a blood pressure measuring module designed to measure the non invasive blo...

Page 3: ...ured the pulsation of the artery as the vibration of the cuff pressure to measure the blood pressure It pressed enough pressure to the cuff wound to the upper arm and the blood flow will stop but the beat of the artery is present also vibration cuff internal pressure in response to it Then when gradually reduce the cuff pressure vibration of the cuff pressure is gradually increases eventually it r...

Page 4: ...tion check Method of operation Wrap the cuff on the arm of the subject Power is supplied to the unit and then to the blood pressure measurement possible state Measurement start and press the stop switch to start the measurement After the measurement remove the cuff from the subject PRECAUTIONS In the case of the following or please carefully apply to the following of the subject The direction from...

Page 5: ... transfusion please do not wound the cuff to a limb that has been vein secured Please do not wound the cuff to the limb with an artificial dialysis shunt Please measure with an appropriate cuff size Doing so may result of measurement error From time to time to check the measurement site please change the measurement site if there is an abnormality Or causing the peripheral circulatory failure rash...

Page 6: ...priate it can cause burns in the subject mounting portion Please carefully read the instruction manual of the electric knife for more information Microwave therapy equipment equipment that generates the noise such as you might not be able to if measured correctly in the vicinity Such as the commercially available personal computer to the external I O connector please do not direct connection with ...

Page 7: ...ch as benzene to clean These solvents will damage the surface of the plastic Inspection before use In appearance there is no deformation such as by dropping Ri was dirty Please check not wet Cuff please make sure that you are using the specified ones Inspection after the power is turned on Smoke or out or there is no strange smell please check whether the abnormal noise is not heard Maintenance an...

Page 8: ...t wipe the electrical connector portion Packing Packed in a single unit Manufacturing distributors and manufacturers of name and address etc Name or name Omron Healthcare Co Ltd First class medical equipment manufacturing and sales Address etc Yubinbango617 0002 Kyoto Muko Terato cho Kyunotsubo 53 address phone number Customer Support Center 0120 103 203 24 hours a day toll free Foreign manufactur...