background image

READ AND UNDERSTAND THIS CATALOG

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions
or comments.

Warranty and Limitations of Liability

WARRANTY

OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if
specified) from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT
THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR
COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY,
NEGLIGENCE, OR STRICT LIABILITY.

In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON’S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND
NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

Application Considerations

SUITABILITY FOR USE

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the
customer’s application or use of the product.

At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply
to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end
product, machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all
possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,

safety equipment, and installations subject to separate industry or government regulations.

• Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT
THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED
AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

Disclaimers

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix
or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

ERRORS AND OMISSIONS

The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.

PERFORMANCE DATA

Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may
represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject
to the OMRON Warranty and Limitations of Liability.

PROGRAMMABLE PRODUCTS

OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.

Copyright and Copy Permission

COPYRIGHT AND COPY PERMISSION

This document shall not be copied for sales or promotions without permission.

This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or
reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in
its entirety.

Summary of Contents for K7L-UP-FLK

Page 1: ...easy to install UL approval List of Models Note 1 The Controller cannot be ordered separately 2 Included with the K7L UP FLK but can be ordered separately Basic configuration Area Separators can be us...

Page 2: ...DC Mechanical 20 million outputs Electrical 80 000 outputs 24 VDC at 5 mA reference value 100 m max default 4 to 20 mA output Allowable load resistance Resolution Error Steady state At error detection...

Page 3: ...in X Y and Z directions Shock resistance 130 m s2 3 times each for 3 axes in six directions Weight Sensor only Approx 185 g Memory protection EEPROM non volatile memory Installation environment Insta...

Page 4: ...8 bits Stop bit length 1 2 bits Set automatically no setting depending on the vertical parity setting Without vertical parity 2 bit With vertical parity 1 bit Error detection Vertical parity none even...

Page 5: ...combination with a button Up Cursor Button Moves the selected item up Moves the selected item up Moves the number or character forward Down Cursor Button Moves the selected item down Moves the selecte...

Page 6: ...disconnection output contacts NC Free terminal 4 Leakage disconnection output contacts 12 External reset 5 RS 485 B 13 External reset 6 RS 485 A NC Free terminal 7 Linear outputs 15 Detect wire Red C...

Page 7: ...e internally isolated Internal Block Diagram 12 13 COM 6 V 4 7 k 7 8 L 500 Max 2 1 Relay 3 4 Relay Power supply circuit X X Linear outputs circuit Drive circuit Reset circuit External reset 4 to 20 mA...

Page 8: ...is function changes the length of the Sensing Cable to any value When there is a discrepancy between the actual length and the measured length this value can be revised to any value for compensation O...

Page 9: ...ession may not be sufficient Dimensions Unit mm Product name Model A Connecting Cable F03 21UP CC B Sensing Cable F03 16UP C M 1 C Area Separator 2 F03 20UP AS D Junction Cable 3 F03 21UP JC E Termina...

Page 10: ...kel Insulation coating Fluororesin Connector materials Metallic parts Brass with nickel plating Resin parts Polyolefine resin Insulation resistance 10 M min Ambient temperature 10 to 55 C Ambient humi...

Page 11: ...pearance Dimensions Junction Cable F03 21UP JC 67 4 7 15 dia 2 050 M12 15 dia 63 Adhesive tape 25 2 15 1 3 5 0 5 1 Material SUS304 Area Separator Leak positions in meters can be divided into up to 20...

Page 12: ...the product in parallel with or bundled with power lines Using separate conduits or ducts and shielded cables can also be effective 14 Do not allow pieces of metal wire clippings or fine metallic sha...

Page 13: ...13 MEMO...

Page 14: ...MEMO 14...

Page 15: ...ons or uses not described in this document Nuclear energy control systems combustion systems railroad systems aviation systems medical equipment amusement machines vehicles safety equipment and instal...

Page 16: ...Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron com Tokyo JAPAN OMRON ASIA PACIFIC PTE LTD No 438A A...

Reviews: