![background image](http://html1.mh-extra.com/html/omron/k7l-up-flk/k7l-up-flk_manual_1633240002.webp)
K7L-UP-FLK
2
Specifications
Ratings
*
This product may not meet the performance that is described in catalog depending on liquid type that is detected. Please make sure to check and test before to buy it.
Detectable chemical
Item
Model
K7L-UP-FLK
Power supply voltage
100 to 240 VAC 50/60 Hz
Allowable voltage fluctuation range
Rated voltage 85 to 110 % (85 to 264 VAC)
Power consumption
10 VA max. (at maximum load)
Detection method
Inductive method
Operate resistance
50k, 100k
Ω
(selectable) Must operate below each sensitivity setting.
*
Release resistance
350 k
Ω
min.
Current when electrodes are shorted
2 mA/AC max.
Wiring length
600 m max. (total of Sensing Cable, Connecting Cable, Junction Cable, Area Separator and general-purpose
cable)
This value is for completely insulated 600-V 3-conductor VCT cable of with a thickness of 0.75 mm
2
. No
more than 10 Junction Cables can be used.
Area Separators are calculated as 10 m each.
Disconnection
detection
function
Detection signal
10 VDC
Detection time
45 s max.
Recovery
After normal wiring
Output
Relay output
NO contacts
×
2 outputs (leakage, disconnection, error output, and alarm output)
Rated load
Resistive load
Inductive load
Service life
Failure rate P value
Contact resistance
3A 250 VAC/30 VDC
3A 250 VAC/30 VDC
1A 250 VAC/30 VDC
Mechanical: 20 million outputs
Electrical: 80,000 outputs
24 VDC at 5 mA (reference value)
100 m
Ω
max. (default)
4 to 20-mA
output
Allowable load resistance
Resolution
Error
Steady state
At error detection
At disconnection detection
At leakage detection
500
Ω
max.
Approx. 10,000
±
1 %FS
4 mA
5 mA
20 mA
6 + 12
×
Leakage locations (m)/L (m) mA
L: Set distance (default: 600 m)
Other functions
Shift, compensation, Area setting, Output setting, Output reset, Output test, Event log,
Key protection, and Backlight ON-time setting
Ambient
temperature
Operating
-10 to 55
°
C (no icing or condensation)
Storage
-25 to 65
°
C (no icing or condensation)
Ambient humidity
Operating
25 to 85 %RH (no condensation)
Storage
25 to 85 %RH (no condensation)
Altitude
2000 m max.
External color
Controller: Ivory
Mounting method
Surface mounting, DIN track mounting
Terminal block
Single-line terminal block (Use ferrules.)
Terminal block tightening torque
0.5 to 0.6 N
•
m
Degree of protection
IP20 (Panel-mounted)
Accessories
Connecting Cable, Terminator, Instruction manual
Type
Name
Another Name
Chemical formula
Alcohol
Methanol
Methyl Alcohol
CH
3
OH
Acid
Hydrochloric Acid
---
HCI
Sulfuric Acid
H
2
SO
4
Nitric Acid
HNO
3
Acetic Acid 98%
CH
3
COOH
Phosphoric Acid
H
3
PO
4
Hydrofluoric Acid
HF
Alkali
Ammonia Solution
28% Ammonia Solution
NH
3
Sodium Hydroxide
Caustic Soda
N
a
OH
Potassium Hydroxide
Caustic Potash
KOH
Other
Sodium Hypochlorite
---
N
a
ClO
Sodium Hydrogen Sulfite
Sodium Bisulfite
N
a
HSO
3
Hydrogen Peroxide
Hydrogen Peroxide 30%
H
2
O
2
Summary of Contents for K7L-UP-FLK
Page 13: ...13 MEMO...
Page 14: ...MEMO 14...