background image

F03-

@@

UP

10

F03-

@@

UP

• Made of fluororesin for superior resistance to 

chemicals.

• Flexible cables make wiring easy.
• There is little out gas, enabling worry-free use in a 

clean room.

Structure and Dimensions

(Unit: mm)

*

 L: 2m, 5m, 10m, 30m

Specifications

Note:

The blank -

@

M suffix in the model number indicates that 2, 5, 

10, or 30 m can be selected. 

• Cable for connecting the Controller and Sensing 

Cable.

Dimensions

(Unit: mm)

Note:

For recommended ferrules, refer to page 12.

Specifications

Sensing Cable Chemical Resistance

A: Not affected at all or only very slightly affected.
B: Slightly affected but, depending on the conditions, sufficient for use.
C: Affected but may still be used. (Replace the Sensing Band immediately after detection.)

Structure

Dimensions

Number of electrodes

3

Cable 
materials

Signal wire

Tin-plated annealed copper

Resistance wire

Kermalloy

Detect wire

Nickel

Insulation coating

Fluororesin

Connector 
materials

Metallic parts

Brass with nickel plating

Resin parts

Polyolefine resin

Insulation resistance

10 M

Ω

 min.

Ambient temperature

-10 to 55 

°

C

Ambient humidity

25 to 85 %

Weight (2m)

Approx. 80 g

Sensing Cable

F03-16UP-C-

@

M

Signal wire

Protective blade 

(fluorocarbon resin)

Insulation (fluorocarbon resin)

Resistance wire

Detect wire

(67)

(5)

(15 dia.)

(L + 50) 

*

M12

(15 dia.)

(63)

Dimensions

Number of electrodes

3

Cable 
materials

Signal wire

Tin-plated annealed copper

Resistance wire

Tin-plated annealed copper

Detect wire

Tin-plated annealed copper

Insulation coating

PVC

Connector 
materials

Metallic parts

Brass with nickel plating

Resin parts

Polyolefine resin

Insulation resistance

10 M

Ω

 min.

Ambient temperature

-10 to 55 

°

C

Ambient humidity

25 to 85 %

Weight

Approx. 82 g

Connecting Cable

F03-21UP-CC

(15 dia.)

(63)

(35)

(20)

(5) Peeling length

(2,020)

(4.7)

(15)

(55)

Liquid

Corrosion resistance

Water

A

Ammonia

B

Hydrochloric acid

C

Sulfuric acid

B

Phosphoric acid

B

Caustic soda

B

Sodium sulfite

B

Sodium hypochlorite

C

Hydrogen fluoride

C

Summary of Contents for K7L-UP-FLK

Page 1: ...easy to install UL approval List of Models Note 1 The Controller cannot be ordered separately 2 Included with the K7L UP FLK but can be ordered separately Basic configuration Area Separators can be us...

Page 2: ...DC Mechanical 20 million outputs Electrical 80 000 outputs 24 VDC at 5 mA reference value 100 m max default 4 to 20 mA output Allowable load resistance Resolution Error Steady state At error detection...

Page 3: ...in X Y and Z directions Shock resistance 130 m s2 3 times each for 3 axes in six directions Weight Sensor only Approx 185 g Memory protection EEPROM non volatile memory Installation environment Insta...

Page 4: ...8 bits Stop bit length 1 2 bits Set automatically no setting depending on the vertical parity setting Without vertical parity 2 bit With vertical parity 1 bit Error detection Vertical parity none even...

Page 5: ...combination with a button Up Cursor Button Moves the selected item up Moves the selected item up Moves the number or character forward Down Cursor Button Moves the selected item down Moves the selecte...

Page 6: ...disconnection output contacts NC Free terminal 4 Leakage disconnection output contacts 12 External reset 5 RS 485 B 13 External reset 6 RS 485 A NC Free terminal 7 Linear outputs 15 Detect wire Red C...

Page 7: ...e internally isolated Internal Block Diagram 12 13 COM 6 V 4 7 k 7 8 L 500 Max 2 1 Relay 3 4 Relay Power supply circuit X X Linear outputs circuit Drive circuit Reset circuit External reset 4 to 20 mA...

Page 8: ...is function changes the length of the Sensing Cable to any value When there is a discrepancy between the actual length and the measured length this value can be revised to any value for compensation O...

Page 9: ...ession may not be sufficient Dimensions Unit mm Product name Model A Connecting Cable F03 21UP CC B Sensing Cable F03 16UP C M 1 C Area Separator 2 F03 20UP AS D Junction Cable 3 F03 21UP JC E Termina...

Page 10: ...kel Insulation coating Fluororesin Connector materials Metallic parts Brass with nickel plating Resin parts Polyolefine resin Insulation resistance 10 M min Ambient temperature 10 to 55 C Ambient humi...

Page 11: ...pearance Dimensions Junction Cable F03 21UP JC 67 4 7 15 dia 2 050 M12 15 dia 63 Adhesive tape 25 2 15 1 3 5 0 5 1 Material SUS304 Area Separator Leak positions in meters can be divided into up to 20...