Note
• F4 is displayed only when "
totl
" is selected in F2 (input selection).
• Alarm ( indicator) will be displayed when either total time (F3) or total
count (F4) reaches the set alarm value.
• If an alarm value for the total count is set to 0, the alarm indicator does not appear.
• To leave initial setting mode, press for 3 s or more.
• If is pressed again before confirming the setting, the setting is
cancelled.
- 51 -
Weekly
2 chnls
Yearly
2 chnls
Yearly
4 chnls
The alarm value can be set for the total count. (
6-1)
Setting
The setting is made in F4 (total count alarm) of initial setting mode.
Press for 3 s or more in program
setting mode to enter initial setting mode.
Give short presses on and
move to the F4 display.
Press to confirm the setting.
(After a one second pause, the screen returns to the initial display of F4.)
WRITE
6-6-4. F4: Total Count Alarm
Setting range
0 to 999900 (6 digits)
Count is set in the hundreds.
The default is 0 (The alarm indicator output is off).
The
color indica
te
s
f
lashing.
TIME AD
J
T
I
ME
AD
J
TIME AD
J
T
I
ME
AD
J
Set the Mode Switch to RUN.
Alarm value setting display appears
automatically in 2 s after entering F4.
Press or to set an alarm value.
decrements the value of the Key that was last pressed.)
: increments in 1,000 hour unit.
: increments in 10 hour unit.
m
h
h
m
(Pressing HOLIDAY/
SELECT PRGM/
or