D40A/G9SX-NS
22
Application Examples
G9SX-NSA222-T0
3
-
@
(24 VDC) (1-channel Emer
g
ency Stop Switch Input + Non-contact Door Switch/Manual Reset)
G9SX-NSA222-T0
3
-
@
(24 VDC) (2-channel Safety Limit Switch Input + Non-contact Door Switch/Auto Reset)
G9SX S14
G9SX S44,S54
Emergency stop switch S1
Non-contact
Door Switch S2
OFF-delay time
Emergency stop
switch operation
OFF-delay time
KM1, KM2 N.C. contact
KM1, KM2 N.O. contact
Operation command
Rotation of motor
Reset switch S3
Timin
g
chart
S14
M1
KM2
KM1
Motor controller
OFF
AND
NC
G9SX-NSA222-T03
Control circuit
KM2
KM1
+24 V
NC
NC
Blac
k
Bro
wn
White
bl
u
e
NC
GND
S3
S2
+24 V
Feedback Loop
+24 V
12
11
S1
Motor controller
(Operation command)
PLC etc.
KM2
KM1
X2
X1
L1
S54
S44
A2
A1
S24
S14
T11 T12 T21 T22 T31 T32 T33
T41 T42
Y1 D1 D2 D3 D4
Non-contact
Door Switch
Actuator
S1: Emergency Stop Switch
S2:
Non-contact Door Switch
S
3
: Reset Switch
KM1, KM2: Contactor
M1:
3
-phase motor
Note: 1.
This example corresponds to category 2.
2.
For details on Non-contact Door Switch wiring, refer to pages 15 and 16
or to the User’s Manual.
open
23
24
11
12
S2
S1
OFF
AND
NC
G9SX-NSA222-T03
Control circuit
KM2
KM1
NC
NC
Blac
k
Bro
wn
White
Blue
S3
+24 V
S14
M1
KM2
KM1
Motor controller
+24 V
GND
Feedback Loop
Motor controller
(Operation command)
PLC etc.
A1
KM2
KM1
X2
X1
L1
S54
S44
A2
S24
S14
T11 T12 T21 T22 T31 T32 T33
T41 T42
Y1 D1 D2 D3 D4
Non-contact
Door Switch
Actuator
G9SX S14
G9SX S44, S54
OFF-delay time
OFF-delay time
Safety limit switch S1
KM1, KM2 N.C. contact
KM1, KM2 N.O. contact
Operation command
Rotation of motor
Limit switch S2
Non-contact
Door Switch S3
Timin
g
chart
S1: Safety limit switch
S2: Limit switch
S
3
: Non-contact Door Switch
KM1, KM2: Contactor
M1:
3
-phase motor
Note: 1.
This example corresponds to category
3
.
2.
For details on Non-contact Door Switch wiring, refer to pages 15 and 16
or to the User’s Manual.