Operation
Functions
Lo
g
ical AND Connection
A logical AND connection means that the G9SX outputs a safety
signal “a” to another G9SX, and that G9SX creates the logical AND of
safety signal “a” and safety signal “
b
.” The safety output of the
G9SX-NSA222-T0
3
-
@
with the logical AND connection shown in the
following diagram is “a” AND “
b
.”
This is illustrated using the application in the following diagram as an
example. The equipment here has two hazards identified as Ro
b
ot 1
and Ro
b
ot 2, and it is equipped with Non-contact Door Switches and
an emergency stop
b
utton as safety measures. If the door to Ro
b
ot 2
is opened, only Ro
b
ot 2 is stopped (i.e., a partial stop). If the door to
Ro
b
ot 1 is opened or the emergency stop
b
utton is pressed,
b
oth
Ro
b
ot 1 and Ro
b
ot 2 stop (i.e., a complete stop).
The actual situation using a G9SX for this application is shown in this
example.
Note:
The logical AND setting on the G9SX-NS202-
@
must
b
e set to
AND (ena
b
led).
*
A manual reset is required when an emergency stop is used.
Connectin
g
Expansion Units
•
The G9SX-EX and G9SX-EX-T Expansion Units can
b
e connected
to a G9SX-NSA222-T
3
-
@
Non-contact Door Switch Controller to
increase the num
b
er of safety outputs. (They cannot
b
e connected
to a G9SX-NS202-
@
.)
•
A maximum of five Expansion Units can
b
e connected to one
G9SX-NSA222-T0
3
-
@
. This may
b
e a com
b
ination of G9SX-EX
instantaneous models and G9SX-EX-T OFF-delayed models.
•
Remove the terminating connector from the receptacle on
G9SX-NSA222-T0
3
-
@
and insert the Expansion Unit ca
b
le
connector into the receptacle. Insert the terminating connector into
the receptacle on the Expansion Unit at the very end (rightmost).
•
When Expansion Units are connected to a Controller, make sure
that power is supplied to every Expansion Unit. (Refer to the
following diagram for actual Expansion Unit connection.)
a
a
b
a (AND) b
G9SX-NSA222-T03-
@
G9SX-NS202-
@
Robot 1
Robot 2
Emergency stop button
Non-contact Door Switch 1
Non-contact Door Switch 2
G9
S
X-
N
S
A222-T03-
@
Robot 1
Robot 2
Emergency
s
top
s
witch
*
D40A
D40A
G9
S
X-
N
S
202-
@
Expansion Unit
Terminating
connector
G9SX-NSA222-T03-
@